Related Experiment Video
Updated: Mar 21, 2026

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Impact of Crown-Implant Ratio of Single Restorations Supported by 6-mm Implants: A Short-Term Case Series Study
Purpose:
High crown-implant ratios might affect the biologic and technical performance of a reconstruction. The aim of this study was to assess whether a higher crown-implant ratio of single restorations on 6-mm implants resulted in more peri-implant bone loss and more prosthetic complications during a 1-year followup period.
Materials And Methods:
A group of 37 patients were provided with 47 single-implant-supported restorations on 6-mm implants. Implants were placed in the posterior mandible or maxilla, where limited bone height was available. The clinical crown-implant ratio was determined on digitized casts. Peri-implant bone changes were analyzed on intraoral radiographs. Prosthetic complications were scored throughout the evaluation period.
Results:
The mean crown-implant ratio was 2.14 ± 0.42. The mean peri-implant bone loss was 0.13 ± 0.36 mm. No complications occurred.
Conclusion:
High crown-implant ratios are not accompanied by increased peri-implant bone changes or prosthetic complications during a 1-year follow-up period.