Related Experiment Video
Updated: Sep 15, 2026

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Short-term pulse rate variability is better characterized by functional near-infrared spectroscopy than by
Lisa Holper1, Erich Seifritz1, Felix Scholkmann2
1University of Zurich, Department of Psychiatry, Psychotherapy, and Psychosomatics, Hospital of Psychiatry, Lenggstrasse 31, 8032 Zurich, Switzerland.
Abstract:
Pulse rate variability (PRV) can be extracted from functional near-infrared spectroscopy (fNIRS) (PRV(NIRS)) and photoplethysmography (PPG) (PRV(PPG)) signals. The present study compared the accuracy of simultaneously acquired PRV(NIRS) and PRV(PPG), and evaluated their different characterizations of the sympathetic (SNS) and parasympathetic (PSNS) autonomous nervous system activity. Ten healthy subjects were recorded during resting-state (RS) and respiratory challenges in two temperature conditions, i.e., room temperature (23°C) and cold temperature (4°C). PRV(NIRS) was recorded based on fNIRS measurement on the head, whereas PRV(PPG) was determined based on PPG measured at the finger. Accuracy between PRV(NIRS) and PRV(PPG), as assessed by cross-covariance and cross-sample entropy, demonstrated a high degree of correlation (r > 0.9), which was significantly reduced by respiration and cold temperature. Characterization of SNS and PSNS using frequency-domain, time-domain, and nonlinear methods showed that PRV(NIRS) provided significantly better information on increasing PSNS activity in response to respiration and cold temperature than PRV(PPG). The findings show that PRV(NIRS) may outperform PRV(PPG) under conditions in which respiration and temperature changes are present, and may, therefore, be advantageous in research and clinical settings, especially if characterization of the autonomous nervous system is desired.
More Related Videos
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
09:33Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
Published on: December 19, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Special considerations while measuring pulse
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse
The pulse serves as a clinical indicator...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...