Objective:
To compare the image quality of conventional arterial and portal venous (PV) phase multidetector CT (MDCT) with two biphasic injection protocols in polytrauma patients.
Methods:
60 consecutive patients with polytrauma underwent body 256-slice MDCT with a conventional protocol or 1 of 2 single-pass biphasic protocols: Group A, arterial (30 s) and PV (60 s) phase acquisitions; Group B, "biphasic" contrast injection with a single acquisition at 60 s; and Group C, "modified biphasic" injection with a single acquisition at a 70-s delay. Images were analyzed for arterial, venous and parenchymal attenuation profiles with regions of interest in the major arteries, veins and solid abdominal organs. A 5-point scoring system was used to assess the image quality, with 5 representing excellent arterial, venous and parenchymal opacification and <3 representing non-diagnostic opacification. In addition, the effective dose (millisieverts) was compared between the groups.
Results:
In 93% of patients, image quality was scored as good or excellent (≥4). All studies were of satisfactory diagnostic quality. Overall, venous and arterial attenuation profiles were comparable. Attenuation profiles in the solid abdominal viscera were significantly higher (p < 0.01) using both biphasic protocols than with arterial or PV phase of conventional protocols. Effective doses were higher in Group A.
Conclusion:
Comparable image quality can be achieved using a biphasic i.v. contrast injection protocol with single MDCT acquisition with less radiation and reduction in acquisition time.
Advances In Knowledge:
For these particular biphasic injection protocols, we have shown that image quality is comparable with a conventional protocol. This has been achieved by comparing enhanced densities of specific structures, as well as gestalt scoring by assessors, on a 256-slice MDCT.