Related Experiment Video
Updated: Mar 21, 2026

Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
Comparative Analysis of Radial Versus Femoral Diagnostic Cardiac Catheterization Procedures in a Cardiology Training
Gurpreet Singh, Enrique Campos, Clifford J Kavinsky
1Division of Cardiology, Rush University Medical Center, 1717 W. Congress Parkway, 317 Kellogg, Chicago, IL 60612 USA. neeraj_jolly@rush.edu.
Objectives:
This study was conducted to evaluate the differences in the procedural variables between transradial and transfemoral access for coronary angiography, with cardiology fellows as the primary operators.
Methods:
This was a retrospective study of 163 radial and 180 femoral access diagnostic cardiac catheterization procedures, and involved cardiology fellowship trainees as primary operators.
Results:
The radial approach was associated with significantly higher fluoroscopy time (8.0 ± 6.97 min vs 4.25 ± 3.01 min; P<.001), dose area product (10775 ± 6724 μGy/m² vs 7952 ± 4236 μGy/m²; P<.001), procedure time (38.31 ± 12.25 min vs 27 ± 17.56 min; P<.001), procedure start to vascular access time (8.24 ± 6.31 min vs 5.31 ± 4.59 min; P<.001), and vascular access to procedure end time (30 ± 15.34 min vs 21.2 ± 9.57 min; P<.001). These differences persisted after adjusting for patients with bypass grafts and additional imaging (P<.001). The contrast amount was not significantly different between the two groups (P=.12). Procedure start to vascular access time improved significantly with fellowship training year in both the radial (9.57 ± 6.96 min vs 8.23 ± 6.08 min vs 5.57 ± 4.82 min) and femoral groups (6.17 ± 5.07 min vs 5.47 ± 4.75 min vs 4.01 ± 3.31 min). Fluoroscopy time showed significant difference in only the femoral access group (P=.01). Dose area product did not improve with training in either access group.
Conclusion:
Radial procedures were associated with higher radiation dose and longer procedure time. Despite decrease in total procedural time for radial cases with the level of training, total radiation dose did not decrease.
More Related Videos
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Cardiac Catheterization IV: Nursing Management
Imaging Studies for Cardiovascular System V: CT