Thera-band(®) elastic band tension: reference values for physical activity
Marco Carlos Uchida1, Márcio Makoto Nishida2, Ricardo Aurélio Carvalho Sampaio3
1Department of Adapted Physical Activity, School of Physical Education, University of Campinas, Brazil; Department of Human Health Sciences, Kyoto University Graduate School of Medicine, Japan.
Abstract:
[Purpose] The aim of this technical note was to report significant differences in the tension forces of the different-sized Thera-band(®) elastic bands (Hygenic Corp.) determined by us versus the manufacturer. [Subjects] Two trained observers performed all measurements. [Methods] The tension force (kilogram-force units) of eight color-coded elastic bands (tan, yellow, red, green, blue, black, silver, and gold) with different resistance levels was measured at 10 different percentages of elongation (25% to 250% with 25% increments) using an electronic elongation gauge tensiometer. [Results] There were significant differences in the tension force of the elastic bands of different colors when compared in pairs (excepting the tan/yellow pair) at 100% and 200% elongation, as determined via one-way analysis of variance. There were no differences in the slopes for the tan versus yellow and green versus blue bands, as determined via linear regression analysis and one-way analysis of variance. Comparison of the tension force values obtained in our study with the reference values of the manufacturer (the t-test applied to the slopes) showed significant differences for five colors (yellow, green, blue, silver, and gold). [Conclusion] Our results indicate that the tension force values for Thera-Band elastic bands provided by the manufacturer are overestimates.
Related Concept Videos
Strain and Elastic Modulus
Pre-Procedural Guidelines for Assessing Blood Pressure
Elastin is Responsible for Tissue Elasticity
Ligaments and tendons are made of dense regular connective tissue, but in ligaments not all fibers are parallel. Dense regular elastic tissue contains elastin fibers and...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes