Otoacoustic emissions in newborns with mild and moderate perinatal hypoxia
Juliana Neves Leite1, Vinicius Souza Silva1, Byanka Cagnacci Buzo1
1Faculdade de Ciências Médicas, Santa Casa de São Paulo, São Paulo, SP, Brasil.
Introduction Severe neonatal hypoxia (as evidenced by the Apgar value) is currently considered the only risk for hearing loss. Hypoxia is one of the most common causes of injury and cell death. The deprivation of oxygen in mild or moderate cases of hypoxia, although smaller, occurs and could cause damage to the auditory system. Objective To investigate the amplitude of otoacoustic emissions in neonates at term with mild to moderate hypoxia and no risk for hearing loss. Methods We evaluated 37 newborns, divided into two groups: a control group of 25 newborns without hypoxia and a study group of 12 newborns with mild to moderate hypoxia. TEOAE and DPOAE were investigated in both groups. Results The differences between groups were statistically significant in the amplitude of DPOAE at the frequencies of 1000, 2800, 4000 and 6000 Hz. In TEOAE, statistically significant differences were found in all tested frequency bands. OAE of the study group were lower than those in the control group. Conclusion Although the occurrence of mild and moderate neonatal hypoxia is not considered a risk factor for hearing loss, deprivation of minimum oxygen during neonatal hypoxia seems to interfere in the functioning of the outer hair cells and, consequently, alter the response level of otoacoustic emissions. Thus, hese children need longitudinal follow-up in order to identify the possible impact of these results on language acquisition and future academic performance.
Introduction Severe neonatal hypoxia (as evidenced by the Apgar value) is currently considered the only risk for hearing loss. Hypoxia is one of the most common causes of injury and cell death. The deprivation of oxygen in mild or moderate cases of hypoxia, although smaller, occurs and could cause damage to the auditory system. Objective To investigate the amplitude of otoacoustic emissions in neonates at term with mild to moderate hypoxia and no risk for hearing loss. Methods We evaluated 37 newborns, divided into two groups: a control group of 25 newborns without hypoxia and a study group of 12 newborns with mild to moderate hypoxia. TEOAE and DPOAE were investigated in both groups. Results The differences between groups were statistically significant in the amplitude of DPOAE at the frequencies of 1000, 2800, 4000 and 6000 Hz. In TEOAE, statistically significant differences were found in all tested frequency bands. OAE of the study group were lower than those in the control group. Conclusion Although the occurrence of mild and moderate neonatal hypoxia is not considered a risk factor for hearing loss, deprivation of minimum oxygen during neonatal hypoxia seems to interfere in the functioning of the outer hair cells and, consequently, alter the response level of otoacoustic emissions. Thus, hese children need longitudinal follow-up in order to identify the possible impact of these results on language acquisition and future academic performance.
Related Concept Videos
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...