Related Experiment Video
Updated: Aug 17, 2026

Hydrogel Nanoparticle Harvesting of Plasma or Urine for Detecting Low Abundance Proteins
Published on: August 7, 2014
Reliability of a urine dipstick in emergency department patients
D A Propp1, D Weber, M L Ciesla
1Division of Emergency Medicine, Lutheran General Hospital, Park Ridge, Illinois 60068.
Abstract:
We conducted a study to examine whether a negative Chemstrip 9 result for leukocyte esterase and nitrite would reliably exclude an abnormal microscopic examination of the urine of emergency department patients. Three hundred urine specimens were subjected to Chemstrip 9 evaluations and full microscopic examinations in the microscopy laboratory. As the microscopy laboratory examination identified lower WBC and bacteria counts, increasing numbers of false-negative urine dipsticks results occurred. The results of our study reveal that the nitrite and leukocyte esterase assays miss significant microscopic findings with corresponding clinical pathology, with the nitrite examination being the less sensitive of the two tests. Based on our results, we believe it would not be prudent to use the Chemstrip 9 dipstick in the ED to exclude the presence of WBC and bacteria in the urine.
Related Concept Videos
Urinary Tract Infection III: Diagnostic Studies and Interprofessional Care
Urine Studies I: Urinalysis
Acute Kidney Injury I: Introduction
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Urine Studies II: Urine Culture and Sensitivity Test