Related Experiment Video
Updated: Mar 21, 2026

Isolation and Identification of Waterborne Antibiotic-Resistant Bacteria and Molecular Characterization of their Antibiotic Resistance Genes
Published on: March 3, 2023
Molecular analysis for bacterial contamination in dental unit water lines
Akari Watanabe1, Naofumi Tamaki2, Miwa Matsuyama1
1Department of Oral Health Care and Rehabilitation, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan.
Abstract:
Bacterial contamination in dental unit waterlines (DUWLs) was evaluated by molecular techniques in addition to the conventional culture method. Water samples (n=8) from DUWLs were investigated for heterotrophic bacteria by culture method using R2A agar. The selected bacterial antibiotic-resistance genes and Legionella species-specific 16SrDNA were identified by PCR. The profiles of bacterial contamination in DUWLs were further identified by PCR-DGGE. In this study, no antibiotic-resistant or Legionella genes were detected. Polycyclic aromatic hydrocarbon-degrading bacterium, Novosphingobium sp. was the most prevalent in DUWLs. Conventional PCR and PCR-DGGE were shown to be potentially useful for monitoring of bacterial contamination in DUWLs.
Related Concept Videos
Applications of Molecular Taxonomy
Automated Microbial Diagnostics