Methodology of method comparison studies evaluating the validity of cardiac output monitors: a stepwise approach and
L J Montenij1, W F Buhre2, J R Jansen3
1Department of Anaesthesiology, Intensive Care and Emergency Medicine, University Medical Centre Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
Abstract:
The validity of each new cardiac output (CO) monitor should be established before implementation in clinical practice. For this purpose, method comparison studies investigate the accuracy and precision against a reference technique. With the emergence of continuous CO monitors, the ability to detect changes in CO, in addition to its absolute value, has gained interest. Therefore, method comparison studies increasingly include assessment of trending ability in the data analysis. A number of methodological challenges arise in method comparison research with respect to the application of Bland-Altman and trending analysis. Failure to face these methodological challenges will lead to misinterpretation and erroneous conclusions. We therefore review the basic principles and pitfalls of Bland-Altman analysis in method comparison studies concerning new CO monitors. In addition, the concept of clinical concordance is introduced to evaluate trending ability from a clinical perspective. The primary scope of this review is to provide a complete overview of the pitfalls in CO method comparison research, whereas other publications focused on a single aspect of the study design or data analysis. This leads to a stepwise approach and checklist for a complete data analysis and data representation.
More Related Videos
12:37Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine
Published on: February 9, 2016
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...