Related Experiment Video
Updated: Mar 20, 2026

Fabrication of Gate-tunable Graphene Devices for Scanning Tunneling Microscopy Studies with Coulomb Impurities
Published on: July 24, 2015
Spin Lifetimes Exceeding 12 ns in Graphene Nonlocal Spin Valve Devices
Marc Drögeler1, Christopher Franzen1, Frank Volmer1
12nd Institute of Physics and JARA-FIT, RWTH Aachen University , 52074 Aachen, Germany.
Abstract:
We show spin lifetimes of 12.6 ns and spin diffusion lengths as long as 30.5 μm in single layer graphene nonlocal spin transport devices at room temperature. This is accomplished by the fabrication of Co/MgO-electrodes on a Si/SiO2 substrate and the subsequent dry transfer of a graphene-hBN-stack on top of this electrode structure where a large hBN flake is needed in order to diminish the ingress of solvents along the hBN-to-substrate interface. Interestingly, long spin lifetimes are observed despite the fact that both conductive scanning force microscopy and contact resistance measurements reveal the existence of conducting pinholes throughout the MgO spin injection/detection barriers. Compared to previous devices, we observe an enhancement of the spin lifetime in single layer graphene by a factor of 6. We demonstrate that the spin lifetime does not depend on the contact resistance area products when comparing all bottom-up devices indicating that spin absorption at the contacts is not the predominant source for spin dephasing.
More Related Videos
Related Concept Videos
Atomic Nuclei: Types of Nuclear Relaxation
In spin–lattice or longitudinal relaxation, the excited spins exchange energy with the surrounding lattice as they return to the lower energy level. Among several mechanisms that contribute to spin–lattice relaxation, magnetic dipolar interactions are significant. Here, the excited nucleus transfers...
Valence Bond Theory
Spin–Spin Coupling Constant: Overview
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must...
Spin–Spin Coupling: One-Bond Coupling
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...

