Comparison of different measuring methods for body temperature in lactating cows under different climatic conditions
Stefanie Ammer1, Christian Lambertz2, Matthias Gauly2
1Department of Animal Sciences,Georg-August-University Göttingen,Germany.
Abstract:
The aim of the research described here was to compare different methods of body temperature (BT) measurements in dairy cows. It was hypothesised that reticular temperature (RET) values reflect the physiological status of the animals in an equivalent way to rectal (RT) and vaginal (VT) measurements. RT, VT and RET temperatures of twelve lactating Holstein-Friesian cows were measured over five consecutive days in June and October 2013. While RT and VT were manually measured three times a day, RET was automatically recorded at 10 min intervals using a bolus in the reticulum. For comparison with RT and VT, different RET values were used: single values at the respective recording times (RET-SIN), and mean (RET-MEAN) and median (RET-MED) values of 2 h prior to RT and VT measurements. Overall, body temperatures averaged 38·1 ± 0·6, 38·2 ± 0·4, 38·7 ± 0·9, 38·5 ± 0·7 and 38·7 ± 0·5 °C for RT, VT, RET-SIN, RET-MEAN and RET-MED, respectively. RT and VT were lower than all RET measurements, while RET-SIN and RET-MED were higher than RET-MEAN (P < 0·001). RET-MEAN and RET-MED values were higher in the morning, whereas RT and VT were greatest in the evening (P < 0·001). Overall, records of RT and VT were strongly correlated (r = 0·75; P < 0·001). In contrast to RET-SIN and RET-MEAN, RET-MED was higher correlated to RT and VT. In June, coefficients were higher between all methods than in October. Relation of barn T to RT and VT was stronger when compared to RET measurements. RET-SIN was higher correlated to barn T than RET-MEAN or RET-MED. Correlation between VT and barn T was strongest (r = 0·48; P < 0·001). In summary, RET-MED showed highest correlation with VT and RT. However, single RET measurements (influenced by water or feed intake) can lead to extreme variations and differences to single VT and RT values.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...