Related Experiment Video
Updated: Mar 20, 2026

Author Spotlight: Assessing the Reliability of Doppler Ultrasound in Measuring Leg Blood Flow
Published on: December 15, 2023
The dynamic control ratio at the equilibrium point (DCRe): introducing relative and absolute reliability scores
Tobias Alt1, Axel J Knicker1, Heiko K Strüder1
1a Institute of Movement and Neuroscience , German Sport University , Cologne , Germany.
Abstract:
Analytical methods to assess thigh muscle balance need to provide reliable data to allow meaningful interpretation. However, reproducibility of the dynamic control ratio at the equilibrium point has not been evaluated yet. Therefore, the aim of this study was to compare relative and absolute reliability indices of its angle and moment values with conventional and functional hamstring-quadriceps ratios. Furthermore, effects of familiarisation and angular velocity on reproducibility were analysed. A number of 33 male volunteers participated in 3 identical test sessions. Peak moments (PMs) were determined unilaterally during maximum concentric and eccentric knee flexion (prone) and extension (supine position) at 0.53, 1.57 and 2.62 rad · s-1. A repeated measure, ANOVA, confirmed systematic bias. Intra-class correlation coefficients and standard errors of measurement indicated relative and absolute reliability. Correlation coefficients were averaged over respective factors and tested for significant differences. All balance scores showed comparable low-to-moderate relative (<0.8-0.9) and good absolute reliability (<10%). Relative reproducibility of dynamic control equilibrium parameters augmented with increasing angular velocity, but not with familiarisation. At 2.62 rad · s-1, high (moment: 0.906) to moderate (angle: 0.833) relative reliability scores with accordingly high absolute indices (4.9% and 6.4%) became apparent. Thus, the dynamic control equilibrium is an equivalent method for the reliable assessment of thigh muscle balance.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
07:52Evaluating Postural Control and Lower-extremity Muscle Activation in Individuals with Chronic Ankle Instability
Published on: September 18, 2020
Related Concept Videos
Distribution Reliability and Automation
Relative Risk
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Relative Motion Analysis - Acceleration
Interpreting R Charts
An R chart plots the range of subsets of measurements collected from a process. Each point on the chart represents the range—defined as the difference between the maximum and minimum...
Constraints and Statical Determinacy