Related Experiment Video
Updated: Mar 20, 2026

Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
Published on: March 13, 2026
Complications of Distal Radius Fractures Treated by Volar Locking Plate Fixation
Abstract:
The current study investigated the incidence of complications after surgery for distal radial fractures. This multicenter retrospective study was conducted at 11 institutions. A total of 824 patients who had distal radius fractures that were treated surgically between January 2010 and August 2012 were identified. The study patients were older than 18 years and were observed for at least 12 weeks after surgery for distal radius fractures with a volar locking plate. Sex, age, fracture type according to AO classification, implants, wrist range of motion, grip strength, fracture consolidation rate, and complications were studied. Analysis included 694 patients, including 529 women and 165 men, with a mean age of 64 years. The mean follow-up period was 27 weeks. The fracture consolidation rate was 100%. There were 52 complications (7.5%), including 18 cases of carpal tunnel syndrome, 12 cases of peripheral nerve palsy, 8 cases of trigger digit, 4 cases of tendon rupture (none of the flexor pollicis longus), and 10 others. There was no rupture of the flexor pollicis longus tendon because careful attention was paid to the relationship between the implant and the tendon. Peripheral nerve palsy may have been caused by intraoperative traction in 7 cases, temporary fixation by percutaneous Kirschner wires in 3 cases, and axillary nerve block in 1 case; 1 case appeared to be idiopathic. Tendon ruptures were mainly caused by mechanical stress. [Orthopedics.2016; 39(5):e893-e896.].
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Bones of the Upper Limb: Ulna