Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility

Raphael Ribeiro de Aquino Freitas1, Maria Angela Tardelli1

  • 1Universidade Federal de São Paulo, São Paulo, SP, Brazil.

Abstract

Related Concept Videos

Automated Microbial Diagnostics01:24

Automated Microbial Diagnostics

Automated diagnostic analyzers have transformed clinical microbiology by providing rapid and reliable methods for pathogen identification and antibiotic susceptibility testing. Among these systems, the Vitek 2 is widely used because it automates the traditionally labor-intensive processes of microbial identification (ID) and antibiotic susceptibility testing (AST), delivering standardized and timely results that are essential for effective patient care.Microbial Identification with ID CardsThe...
9
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence01:22

Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence

Generic intravenous (IV) drugs are considered bioequivalent to their branded counterparts due to their 100% bioavailability upon administration. However, variations in stability among different drug products can significantly influence their therapeutic performance, even if they are pharmaceutically equivalent.Cefuroxime, a prophylactic antimicrobial, is often used as a single-dose IV injection for patients undergoing coronary artery bypass grafting surgery. A 3 g dose typically provides...
236
Key Techniques in Microbiology01:19

Key Techniques in Microbiology

Aseptic techniques prevent contamination, ensure experimental accuracy, and protect researchers and microbial cultures. These techniques are essential in clinical, industrial, and research settings where sterility is required.Maintaining Sterility in Laboratory PracticesScientists maintain sterility by sterilizing tools with heat or chemicals, disinfecting work surfaces, and handling cultures in controlled environments. Working near an open flame or within a laminar flow hood reduces the risk...
2.9K
Methods of Sterilization I: Physical Methods01:29

Methods of Sterilization I: Physical Methods

As used in a healthcare facility, sterilization destroys all microorganisms through physical or chemical methods. The physical method includes steam, dry heat, boiling water, and radiation.
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
25.3K
Techniques for Isolation of Pure Cultures01:24

Techniques for Isolation of Pure Cultures

Microorganisms are routinely cultured in the laboratory using various techniques to isolate, grow, and quantify them for further study. These methods rely on inoculating microorganisms into a suitable growth medium under aseptic conditions to prevent contamination. Depending on the objective, inoculation can involve direct transfer or the use of diluted bacterial suspensions as the inoculum.Streak-Plate Method for IsolationThe streak-plate method is a common technique for obtaining pure...
3.5K
Physical Methods for Controlling Microbial Growth: Radiation and Filtration01:26

Physical Methods for Controlling Microbial Growth: Radiation and Filtration

Radiation and filtration are essential tools for microbial control, targeting microorganisms through distinct mechanisms. Radiation eliminates microbes by damaging their DNA, either killing them or inhibiting their growth. Based on wavelength, radiation is classified into two types: nonionizing and ionizing radiation.Non-ionizing radiation, such as UV radiation (200–400 nm), is absorbed by DNA, causing defects that effectively disinfect surfaces, air, and water, including safety cabinets.