Head orientation should be considered in ultrasound studies on carotid artery distensibility
Robert J Holtackers1, Bart Spronck, Maarten H G Heusinkveld
1aDepartment of Radiology bDepartment of Biomedical Engineering cCARIM School for Cardiovascular Diseases dDepartment of Internal Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands.
Introduction:
During ultrasound distensibility assessment of the carotid artery, the patient's head is usually rotated sideward and slightly upward to optimize visibility of the carotid segment. Head rotation may affect vessel length and thus the longitudinal strain of the arterial segment. Because the longitudinal and circumferential mechanical behaviour of an artery are intrinsically related, head rotation may influence circumferential mechanics and thereby measured distensibility.
Methods:
In 12 apparently healthy volunteers (age 22 ± 3 years, mean ± SD, 6 men/6 women), we investigated whether head rotation led to a change in absolute and relative distension of the common carotid artery (CCA) by performing ultrasound examinations with the head in two orientations. Additionally, CCA length was measured in both orientations with MRI to assess whether indeed a change in length occurred because of head rotation. Rotation-induced longitudinal strain was calculated from these lengths.
Results:
We found a significant decrease of 0.054 mm (6.8%, P = 0.001) and 0.007 (5.6%, P = 0.019) in absolute and relative distension with head rotation, respectively. MRI measurements showed a significant rotation-induced longitudinal strain of 1.7 ± 2.3% (P = 0.032).
Conclusion:
We conclude that consistent head rotation during a CCA ultrasound assessment causes a significant and clinically relevant bias in carotid artery distension measurements. The impact of unstandardized use of head rotation in studies with carotid distensibility as an outcome measure can therefore not be neglected; thus, standardization is highly recommendable.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...