Loosely coupled coaxial TEM applicators for deep-heating.

W H Harrison1, F K Storm

  • 1UCLA Medical Center.

International Journal of Hyperthermia : the Official Journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group
|May 1, 1989
PubMed
Summary

A novel non-contacting applicator, the Electrostatic Applicator (ESA), achieves uniform deep-heating in phantom and animal models. This transverse electromagnetic device shows potential for effective hyperthermia treatment with minimal surface heating and patient movement interference.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The role of frozen section analysis of margins during breast conservation surgery.

The cancer journal from Scientific American·1997
Same author

Heat shock protein 27 stimulates recovery of RNA and protein synthesis following a heat shock.

Journal of cellular biochemistry·1997
Same author

Heat shock protein 27 overexpression in breast cancer lymph node metastasis.

Annals of surgical oncology·1996
Same author

Lack of association between tumor necrosis and hsp-27 expression in primary breast cancer.

Journal of surgical oncology·1996
Same author

Interleukin-2 does not sequester activated lymphocytes into lung lymph of sheep.

The Journal of surgical research·1996
Same author

Re: "Cancer risks associated with occupational exposure to magnetic fields among electric utility workers in Ontario and Quebec, Canada, and France: 1970-1989".

American journal of epidemiology·1995

Area of Science:

  • Biomedical Engineering
  • Electromagnetic Therapy
  • Medical Device Development

Background:

  • Deep-heating applicators are crucial for effective hyperthermia treatments.
  • Non-contacting applicators reduce patient discomfort and setup complexity.
  • Achieving uniform heating in deep tissues remains a challenge.

Purpose of the Study:

  • To describe the development of a novel coaxial transverse electromagnetic (TEM) deep-heating applicator.
  • To evaluate the heating characteristics and performance of this non-contacting applicator, named the ESA.
  • To assess the ESA's efficacy in phantom and animal models for potential clinical application.

Main Methods:

  • Development of a coaxial TEM applicator with two axially spaced concentric sleeves.

Related Experiment Videos

  • Thermal measurements using an FDA/CDRH elliptic human torso phantom with fat overlay.
  • Saline tank measurements on a torso cross-section.
  • In vivo animal experiments on a pig, with and without blood flow.
  • Main Results:

    • The ESA demonstrated nearly uniform heating (+/- 10%) within the phantom's inner cross-section.
    • Saline tank measurements confirmed similar specific absorption rate (SAR) uniformity.
    • Animal experiments verified deep-heating capabilities, with some preferential central heating observed.
    • Minimal surface heating and minor effects from patient movement were noted.

    Conclusions:

    • The coaxial TEM ESA is an effective non-contacting applicator for deep-tissue hyperthermia.
    • Its design ensures uniform heating with minimal surface absorption.
    • The ESA shows promise for improved patient outcomes in thermal therapies.