Updated: Mar 20, 2026

Sampling, Sorting, and Characterizing Microplastics in Aquatic Environments with High Suspended Sediment Loads and Large Floating Debris
Published on: July 28, 2018
Robustness of plastic scintillation microspheres in the continuous measurement of different river waters
A Tarancón1, O Novella2, M Batlle2
1Department of Analytical Chemistry, University of Barcelona, Martí i Franqués, 1-11, 08028 Barcelona, Spain.
Abstract:
Plastic scintillation microspheres (PSm) represent one of the most promising options for monitoring alpha and beta radioactivity in river water. For that reason, a study of the stability of PSm packed into a cell against the continuous flow of river water with different degrees of turbidity was performed over a period of 100h. The results showed that the volume of the cell became stable after 15h of pumping and continued to be stable throughout the 100h of the experiment. During this period of time, the detection efficiency of the PSm, in terms of efficiency*volume, presented mean values of 0.75(3)% for (3)H and 272(11)% for (90)Sr/(90)Y. No dependence on flow time or river water type was observed. The background was also constant for 100h and for the different water types, although (222)Rn should be removed from the water beforehand to prevent its accumulation in the PSm. Since PSm did not present any degradation throughout the whole experiment, PSm can undoubtedly be used for monitoring radioactivity with low reagent consumption, low waste generation and low maintenance costs.