Transient and persistent conduction abnormalities following transcatheter aortic valve replacement with the
Solomon J Sager1,2, Abdulla A Damluji3, Joshua A Cohen3
1Cardiovascular Division and Elaine and Sydney Sussman Cardiac Catheterization Laboratory, University of Miami Miller School of Medicine, Miami, FL, USA. sjsager@gmail.com.
Background:
Electrocardiographic conduction abnormalities following transcatheter aortic valve replacement (TAVR) with the Edwards-Sapien valve (ESV) are not uncommon and may be transient. We sought to examine the clinical time-course of conduction abnormalities after TAVR with ESV and determine risk factors for persistent abnormalities.
Methods:
In this single-center prospective study, 116 consecutive patients underwent implantation of the ESV after approval by the Food and Drug Administration (FDA). Demographic, clinical, and intra-procedural variables were collected in a registry, including ECGs before, immediately after, and at discharge from hospital. Conduction abnormalities were analyzed including PR interval lengthening, QRS widening, left bundle branch block (LBBB), and high-grade AV block.
Results:
There were 92 patients included in the analysis. A total of 41 new conduction abnormalities were observed in 31 (34 %) patients: 7 new PR prolongation, 14 QRS widening, 14 new LBBB, and 5 high-grade AV block requiring permanent pacemaker. Of the 41 new CAs, 11 (27 %) were transient; of the transient abnormalities, 9 (82 %) resolved within 24 h of the index procedure. Chronic kidney disease was a risk factor for the development of a persistent abnormality and for need for PPM. Antegrade approach was associated with the development of persistent LBBB and persistent QRS widening.
Conclusions:
A significant proportion of conduction abnormalities after ESV implantation improved prior to discharge from the hospital, usually within 24 h. CKD is associated with persistence of abnormalities and with need for PPM. Antegrade approach increases risk for new intraventricular conduction delays, including LBBB.
More Related Videos
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations