Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
A modified breathing pattern improves the performance of a continuous capnodynamic method for estimation of effective
Caroline Hällsjö Sander1,2, Thorir Sigmundsson3,4, Magnus Hallbäck5
1Department of Anaesthesiology, Surgical Services and Intensive Care Medicine, Karolinska University Hospital, 171 76, Solna, Stockholm, Sweden. caroline.hallsjo-sander@karolinska.se.
Abstract:
In a previous study a new capnodynamic method for estimation of effective pulmonary blood flow (COEPBF) presented a good trending ability but a poor agreement with a reference cardiac output (CO) measurement at high levels of PEEP. In this study we aimed at evaluating the agreement and trending ability of a modified COEPBF algorithm that uses expiratory instead of inspiratory holds during CO and ventilatory manipulations. COEPBF was evaluated in a porcine model at different PEEP levels, tidal volumes and CO manipulations (N = 8). An ultrasonic flow probe placed around the pulmonary trunk was used for CO measurement. We tested the COEPBF algorithm using a modified breathing pattern that introduces cyclic end-expiratory time pauses. The subsequent changes in mean alveolar fraction of carbon dioxide were integrated into a capnodynamic equation and effective pulmonary blood flow, i.e. non-shunted CO, was calculated continuously breath by breath. The overall agreement between COEPBF and the reference method during all interventions was good with bias (limits of agreement) 0.05 (-1.1 to 1.2) L/min and percentage error of 36 %. The overall trending ability as assessed by the four-quadrant and the polar plot methodology was high with a concordance rate of 93 and 94 % respectively. The mean polar angle was 0.4 (95 % CI -3.7 to 4.5)°. A ventilatory pattern recurrently introducing end-expiratory pauses maintains a good agreement between COEPBF and the reference CO method while preserving its trending ability during CO and ventilatory alterations.
More Related Videos
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes and Capacities I
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: