[Identification of Volatile Chemical Constituents from Hui Formula "Ha Hei Lili" by GC-MS]
Objective:
The volatile components of the Hui formula "Ha Hei Lili" were extracted by steam distillation extraction (SD) and supercritical CO2 fluid extraction, and the structures were analyzed and identified by GC-MS.
Methods:
The GC-MS conditions were set as follows: Rxi-5Sil MS quartz capillary column (30 m x 0.25 mm, 0.25 μm), the initial temperature of 50 degrees C to keep 1 min, to 10 degrees C/min heating to 120 degrees C, maintained 3 min, then to 3 degrees C/min heating to 200 degrees C, maintained 3 min, and then to 5 degreesC/min heating to 290 degrees C, maintained until completion of analysis; helium as the carrier gas, column flow rate 1.0 ml/min, split ratio 25: 1, inlet temperature 250 degrees C, EI ionization source 70 eV, ion source temperature 230 degrees C, scan range of m/z 35 - 500.
Results:
Yield of volatile oil were 0.21% and 5.44% extracted by SD and SFE methods, respectively; and for SD method, 36 kinds of compounds were identified, accounted for 87.02% of total mass of volatile oil; for SFE method, 38 kinds of constituents were identified, accounted for 97.47% of total mass of volatile oil.
Conclusion:
The type of constituents contained in the volatile oil extracted by SD and SFE methods are totally different; and GC-MS can be used to identify the structures and relative content of volatile components, the results of this study can provide an experimental basis for development and utilization of Hui formula "Ha Hei Lili".
More Related Videos
07:16Preparation of Gynura bicolor DC samples for High-Resolution Tandem Mass Spectrometry
Published on: February 2, 2024
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Resolution Mass Spectrometry (HRMS)
Volatilization
Mass Spectrum: Interpretation