Cerebral Oxygenation and Acceleration in Pediatric and Neonatal Interfacility Transport
Michael E Valente1, Judy A Sherif1, Colleen G Azen2
1Division of Emergency and Transport Medicine, Children's Hospital Los Angeles, CA, USA.
Objective:
The purpose of this study is to measure peak acceleration forces during interfacility transport; examine whether drops in cerebral oxygenation occurred; and test the associations between cerebral oxygenation, acceleration, and patient positioning.
Methods:
A cerebral oximeter (INVOS-5100C; Somanetics, Minneapolis, MN) monitored regional saturation of oxygen (rSO2 [cerebral oxygenation]) in pediatric and neonatal patients (N = 24) transported between facilities by ground ambulance, helicopter, or fixed wing aircraft. An accelerometer (GP1; SENSR, Georgetown, TX) bolted to the isolette or gurney recorded z-axis (aligned with the spine) accelerations.
Results:
The z-axis peak accelerations (absolute values of g) by transport type were as follows: ground ambulance takeoff mean = 0.16 and landing mean = 0.08, helicopter takeoff mean = 0.16 and landing mean = 0.05, fixed wing aircraft takeoff mean = 0.14 and landing mean = 0.20. During takeoff, 2 of 7 patients in the head-to-front of vehicle position experienced rSO2 drop. During landing, 4 of 13 patients in the head-to-back of vehicle position experienced rSO2 drop. There were no significant associations of rSO2 drop during takeoff and landing with patient positioning or with z-axis peak acceleration.
Conclusion:
Acceleration forces of pediatric and neonatal interfacility transport are small and comparable in magnitude. The relationship between rSO2 drop and patient positioning was not significant in this pilot study.
More Related Videos
07:27How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
05:45Delivery of In Vivo Acute Intermittent Hypoxia in Neonatal Rodents to Prime Subventricular Zone-derived Neural Progenitor Cell Cultures
Published on: November 2, 2015
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Transport in the Blood
Acute Respiratory Failure-IV