Thoracic Aorta Dimension Changes During Systole and Diastole: Evaluation with ECG-Gated Computed Tomography
Jian-Ping Guo1, Xin Jia1, Zhe Sai1
1Vascular Surgery Department, Chinese PLA General Hospital, Beijing, China.
Background:
This study was conducted to characterize the differences in the dimensions between systole and diastole in thoracic aorta in Chinese population with electrocardiogram (ECG)-gated multidetector computed tomography angiography (CTA) scans.
Methods:
The CTAs of 56 patients (mean age 58.2 ± 17.9 years; 42 men, 14 women) both in systole and diastole were obtained on a 64-slice ECG-gated multidetector CT scanner. Four anatomic levels of the thoracic aorta were selected for analysis (Level A: 1 cm proximal to the innominate artery; Level B: 1 cm distal to the left common carotid artery; Level C: 1 cm distal to the left subclavian artery; and Level D: 10 cm distal to the left subclavian artery). On each level, the maximal and the minimal diameters were measured both in systole and diastole.
Results:
The paired sample t-test results showed a significant difference between the systolic and diastolic diameters in all individual subjects on every level. The diameter differences range between -1.7 mm (diastolic dimension is greater than systolic dimension) and 3.6 mm (systolic dimension is greater than diastolic dimension). The aortic diameters in diastolic phase are greater than in systolic phase in 18-22% subjects on different levels. A mean maximum diameter change of 2.68% (range -3.45% to 8.25%) and a mean minimum diameter change of 2.71% (range -5.05% to 8.38%) were found at Level A; a maximum diameter change of 2.89% (range -4.5% to 13.3%) and a minimum diameter change of 2.37% (range -5.2% to 14.9%) were found at Level B; a maximum diameter change of 2.81% (range -6.02% to 10.85%) and a minimum diameter change of 2.92% (range -7.14% to 9.62%) were found at Level C; and a maximum diameter change of 3.08% (range -1.76% to 10.36%) and a minimum diameter change of 2.93% (range -2.37% to 11.9%) were found at Level D.
Conclusions:
Our study verifies that the dimensional differences in thoracic aorta between systolic and diastolic phase are significant. But the pulsatility of thoracic aorta in Chinese population might be different from published literature.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
09:05Assessment of Cardiac Morphological and Functional Changes in Mouse Model of Transverse Aortic Constriction by Echocardiographic Imaging
Published on: June 21, 2016
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Thoracic Aorta
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System V: CT
The Aorta
The average diameter of the aorta is approximately 2-3 cm, but the size can vary depending on the section of the aorta and the individual's age, sex, and body size. The aorta is...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...