Related Experiment Video
Updated: Mar 20, 2026

The Fabrication and Operation of a Continuous Flow, Micro-Electroporation System with Permeabilization Detection
Published on: January 7, 2022
Single-step electrical field strength screening to determine electroporation induced transmembrane transport
Gadi Blumrosen1, Alireza Abazari2, Alexander Golberg3
1Department of Computer Science, Tel Aviv University, Israel.
Abstract:
The design of effective electroporation protocols for molecular delivery applications requires the determination of transport parameters including diffusion coefficient, membrane resealing, and critical electric field strength for electroporation. The use of existing technologies to determine these parameters is time-consuming and labor-intensive, and often results in large inconsistencies in parameter estimation due to variations in the protocols and setups. In this work, we suggest using a set of concentric electrodes to screen a full range of electric field strengths in a single test to determine the electroporation-induced transmembrane transport parameters. Using Calcein as a fluorescent probe, we developed analytical methodology to determine the transport parameters based on the electroporation-induced pattern of fluorescence loss from cells. A monolayer of normal human dermal fibroblast (NHDF) cells were pre-loaded with Calcein and electroporated with an applied voltage of 750V with 10 and 50 square pulses with 50μs duration. Using our analytical model, the critical electric field strength for electroporation was found for the 10 and 50 pulses experiments. An inverse correlation between the field strength and the molecular transport time decay constant, and a direct correlation between field strength and the membrane permeability were observed. The results of this work can simplify the development of electroporation-assisted technologies for research and therapies.
More Related Videos
08:06Author Spotlight: Optimizing Porous Substrate Electroporation Through Micro and Nanochannels for Enhanced Monitoring and Intermediate Stage Characterization
Published on: September 27, 2024
10:12Monitoring Electroporation-Induced Changes in Action Potential Generation in Genetically Engineered Tet-On Spiking HEK cells
Published on: September 6, 2024