Can Bias Evaluation Provide Protection Against False-Negative Results in QT Studies Without a Positive Control Using
Georg Ferber1, Meijian Zhou2, Corina Dota3
1Statistik Georg Ferber GmbH, Riehen, Switzerland.
Abstract:
The revised ICH E14 document allows the use of exposure-response analysis to exclude a small QT effect of a drug. If plasma concentrations exceeding clinically relevant levels is achieved, a positive control is not required. In cases when this cannot be achieved, there may be a need for metrics to protect against false-negative results. The objectives of this study were to create bias in electrocardiogram laboratory QT-interval measurements and define a metric that can be used to detect bias severe enough to cause false-negative results using exposure-response analysis. Data from the IQ-CSRC study, which evaluated the QT effect of 5 QT-prolonging drugs, were used. Negative bias using 3 deterministic and 2 random methods was introduced into the reported QTc values and compared with fully automated data from the underlying electrocardiogram algorithm (COMPAS). The slope estimate of the Bland-Altman plot was used as a bias metric. With the deterministic bias methods, negative bias, measured between electrocardiogram laboratory values and COMPAS, had to be larger than approximately -20 milliseconds over a QTcF range of 100 milliseconds to cause failures to predict the QT effect of ondansetron, quinine, dolasetron, moxifloxacin, and dofetilide. With the random methods, the rate of false-negatives was ≤5% with bias severity < -10 milliseconds for all 5 drugs when plasma levels exceeded those of interest. Severe and therefore detectable bias has to be introduced into reported QTc values to cause false-negative predictions with exposure-response analysis.
More Related Videos
04:56Detection of Helicobacter pylori Infection and Antibiotic Resistance via Stool Quantitative Polymerase Chain Reaction Analysis
Published on: May 16, 2025
08:37Development of a Quantitative Recombinase Polymerase Amplification Assay with an Internal Positive Control
Published on: March 30, 2015
Related Concept Videos
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Controls in Experiments
Detection of Gross Error: The Q Test
Bias in Epidemiological Studies
Cochran's Q Test
Accuracy and Errors in Hypothesis Testing
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5%...