Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Development of an automatic Doppler flow signal detection system: variability of pulmonary and aortic peak flow
Chiho Morita1, Takaaki Nakatsu2, Shozo Kusachi3
1Department of Medicine and Medical Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan.
Purpose:
Automatic Doppler flow signal detection systems can provide beat-to-beat information for large blood vessels. We have developed new equipment for automatic measurement of Doppler flow signals. The reliability of the system was examined, and the variability of aortic and pulmonary peak flow velocity was determined.
Methods:
We measured peak flow velocity using a newly developed system in healthy volunteers and patients with atrial fibrillation. Analysis of variability of peak flow velocity was performed with maximal entropy methods.
Results:
In Bland-Altman plots, the mean and standard deviation (SD) of differences in aortic peak flow velocities between the automatic and manual measurements were 0.22 ± 0.75 cm/s and 0.85 ± 0.38 cm/s, respectively, in five normal volunteers. Moreover, less than 5% of the plotted points were beyond ± 2 SD of the differences. Furthermore, good reproducibility was demonstrated using Bland-Altman plots and Pearson's correlation analysis. Identical reliability was obtained in patients with atrial fibrillation. The same results were obtained for pulmonary peak flow velocity. In five healthy subjects, aortic and pulmonary peak flow showed standard deviations of 7.2 ± 2.4 and 3.8 ± 0.6 cm/s, respectively, and coefficients of variation of 6.1% ± 1.0% and 5.1% ± 1.1%, respectively, in time-domain variability. Similarly, frequency-domain variability was obtained for both peak flow velocities.
Conclusion:
The present study demonstrated the reliability of a newly developed automatic Doppler flow signal detection system. Using this system, the present study demonstrated for the first time aortic and pulmonary peak flow velocity variability. The present analytical methods may have considerable potential for studying aortic and/or pulmonary flow variability in connection with cardiac performance and prognosis of cardiac disease.
More Related Videos
08:08Increasing Pulmonary Artery Pulsatile Flow Improves Hypoxic Pulmonary Hypertension in Piglets
Published on: May 11, 2015
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pipe Flowrate Measurement
The orifice meter is a simple,...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Pipe Flowrate Measurement: Problem Solving
Measurement of Blood Pressure