A novel method to reduce noise in electroretinography using skin electrodes: a study of noise level, inter-session
Tsutomu Yamashita1,2, Atsushi Miki3,4, Akio Tabuchi3
1Department of Sensory Science, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki, 701-0193, Japan. tsutomu-y@mw.kawasaki-m.ac.jp.
Abstract:
To determine the feasibility of recording reproducible electroretinograms (ERGs) with skin electrodes using a new ERG system. Seventeen healthy volunteers were studied. The dark-adapted, bright-flash ERGs were recorded with a new ERG recording system (LE-4000, Tomey, Nagoya, Japan) in which the stimulus alternated between the eyes every 15 s, and each eye was stimulated eight times. The active skin electrode was placed on the lower eyelids of both eyes. The voltage changes of the non-stimulated eye were subtracted from that of the stimulated eye to try to increase the signal-to-noise ratio for eight stimulus cycles. The noise levels were measured from 12 subjects with and without the subtraction steps. ERGs were also recorded on five different days from five subjects, and the coefficient of variation (CV) and the intra-class correlation coefficients (ICCs) were calculated. The noise level without the subtraction step was 18.4 ± 8.4 μV, and it was significantly reduced to 13.8 ± 4.0 μV with the subtraction step (P = 0.001). Reproducible ERGs were obtained from each subject, and the average CV for the five subjects was 6.1 % for the a-wave amplitude, 7.7 % for the b-wave amplitude, and 7.7 % for the sum of the oscillatory potential (OP) amplitude. The ICC was 0.76 for the a-wave amplitude, 0.68 for the b-wave amplitude, and 0.72 for the sum of the OPs amplitude. These findings indicate that our new ERG recording methods shows noise reduction and good reproducibility with low inter-session variability even with skin electrodes.
Related Concept Videos
Graphs of Equations in Two Variables
Introduction and Methods of Leveling
Methods of reducing fever
Pharmacological Methods of Reducing Fever:
Standard Electrode Potentials
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...