Early detection of incorrect siting of Procter-Livingstone tube by fibre-optic endoscopy
1Department of Surgery, Umtata General Hospital, Transkei.
Abstract:
Forty patients undergoing intubation with a Procter-Livingstone tube for oesophageal neoplasm were checked by gastroscope for correctness of placement. An end-viewing fibre-optic scope was passed through the rigid oesophagoscope, through the Procter-Livingstone tube and onwards into whatever structure lay beyond. Oesophageal perforation occurred in 6 patients and immediate salvage operations resulted in 4 surviving. Reduced hospital mortality and educational feedback for the operator were the major advantages.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...