Related Experiment Video
Updated: Mar 19, 2026

Echocardiographic Assessment of Cardiac Anatomy and Function in Adult Rats
Published on: December 13, 2019
Gender differences of pulsed and tissue Doppler indexes of left ventricular diastolic function in healthy subjects
Takenori Otsuka1,2, Makoto Suzuki3, Hisao Yoshikawa3
1Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-1-17 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan. nori3649@hotmail.com.
Background:
The purpose of this study is to determine the normative Doppler values and gender differences in left ventricular (LV) diastolic function in healthy subjects at each decade of life.
Methods:
Four hundred sixty-seven male and 455 female healthy subjects, aged 20-90 years, underwent standard echocardiography and tissue Doppler imaging. We divided the subjects into seven groups, based on the decade of their age (i.e., 20s, 30s, 40s, 50s, 60s, 70s, and 80s), and measured standard echocardiographic parameters and Doppler indices.
Results:
Females younger than 50 years had significantly higher mitral E velocity, and females older than 40 years had significantly higher mitral A velocity, compared with their male counterparts. There was no difference in mitral E to A velocity ratio (E/A) at any age. The tissue Doppler method showed significantly lower early diastole velocity of the mitral annulus (E a) in females-especially females older than 50 years-than in males (10.7 ± 3.7 versus 11.2 ± 3.7 cm/s, p < 0.025). Mean E/E a ratio was higher in females than in males (6.9 ± 2.4 versus 6.0 ± 2.0, p < 0.0001).
Conclusion:
Our results indicate gender differences in Doppler indexes of LV diastolic function in healthy subjects. In clinical settings, assessment of LV diastolic function using the Doppler method should take into account patient gender.
More Related Videos
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
Related Concept Videos
Special considerations while measuring pulse
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Pulse
The pulse serves as a clinical...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: