Pentobarbital quantitation using immunoassays in Reye's syndrome patient serum
1Department of Pediatric Pathology, Arkansas Children's Hospital, Little Rock 72202.
Therapeutic Drug Monitoring
|January 1, 1989
Summary
Immunoassay methods reliably quantify serum pentobarbital concentrations in Reye's syndrome patients. These techniques, including enzyme-multiplied immunoassay technique (EMIT) and fluorescence polarization immunoassay (FPI), show excellent agreement with high-performance liquid chromatography (HPLC).
Area of Science:
- Clinical Chemistry
- Toxicology
- Pharmacology
Background:
- Accurate measurement of serum pentobarbital is crucial for managing Reye's syndrome.
- Existing immunoassay methods require adaptation for precise serum pentobarbital quantitation.
Purpose of the Study:
- To adapt and evaluate immunoassay techniques for accurate serum pentobarbital measurement in Reye's syndrome patients.
- To compare the performance of adapted immunoassays against a high-performance liquid chromatography (HPLC) reference method.
Main Methods:
- Modified urine enzyme-multiplied immunoassay technique (EMIT) Dupont aca barbiturate screen for serum pentobarbital quantitation.
- Adaptation of urine fluorescence polarization immunoassay (FPI) screen for serum pentobarbital analysis.
- Comparison of immunoassay results with HPLC using regression and multiple linear regression analyses.
Main Results:
- Adapted EMIT and FPI methods demonstrated high precision (less than 6% between-day variability).
- Excellent agreement was observed between immunoassay methods and HPLC (r = 0.97).
- Multiple regression analysis confirmed concordance among all tested immunoassay techniques.
Conclusions:
- Adapted immunoassays provide a reliable and accurate approach for quantifying serum pentobarbital.
- These methods offer a viable alternative to HPLC for therapeutic drug monitoring in Reye's syndrome.
- Immunoassay techniques are suitable for routine clinical laboratory analysis of serum pentobarbital.