Related Experiment Video
Updated: Mar 19, 2026

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
Patient-specific pharmacokinetic parameter estimation on dynamic contrast-enhanced MRI of prostate: Preliminary
Shoshana B Ginsburg1, Pekka Taimen2, Harri Merisaari3,4,5
1Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.
Purpose:
To develop and evaluate a prostate-based method (PBM) for estimating pharmacokinetic parameters on dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) by leveraging inherent differences in pharmacokinetic characteristics between the peripheral zone (PZ) and transition zone (TZ).
Materials And Methods:
This retrospective study, approved by the Institutional Review Board, included 40 patients who underwent a multiparametric 3T MRI examination and subsequent radical prostatectomy. A two-step PBM for estimating pharmacokinetic parameters exploited the inherent differences in pharmacokinetic characteristics associated with the TZ and PZ. First, the reference region model was implemented to estimate ratios of Ktrans between normal TZ and PZ. Subsequently, the reference region model was leveraged again to estimate values for Ktrans and ve for every prostate voxel. The parameters of PBM were compared with those estimated using an arterial input function (AIF) derived from the femoral arteries. The ability of the parameters to differentiate prostate cancer (PCa) from benign tissue was evaluated on a voxel and lesion level. Additionally, the effect of temporal downsampling of the DCE MRI data was assessed.
Results:
Significant differences (P < 0.05) in PBM Ktrans between PCa lesions and benign tissue were found in 26/27 patients with TZ lesions and in 33/38 patients with PZ lesions; significant differences in AIF-based Ktrans occurred in 26/27 and 30/38 patients, respectively. The 75th and 100th percentiles of Ktrans and ve estimated using PBM positively correlated with lesion size (P < 0.05).
Conclusion:
Pharmacokinetic parameters estimated via PBM outperformed AIF-based parameters in PCa detection. J. Magn. Reson. Imaging 2016;44:1405-1414.
More Related Videos
Related Concept Videos
Pharmacokinetic–Pharmacodynamic Relationship: Problems
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Pharmacokinetic–Pharmacodynamic Relationship: Model Components
Dosage Regimens: Partial Pharmacokinetic Parameters
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's...

