Health Economic Impact of a Pulmonary Artery Pressure Sensor for Heart Failure Telemonitoring: A Dynamic Simulation
Peter L Kolominsky-Rabas1,2, Christine Kriza1,2, Anatoli Djanatliev3
11 Interdisciplinary Centre for Health Technology Assessment (HTA) and Public Health, Friedrich-Alexander-Universität Erlangen-Nürnberg Erlangen , Germany .
Aims:
Recently, a permanently implantable wireless system, designed to monitor and manage pulmonary artery (PA) pressures remotely, demonstrated significant reductions in heart failure (HF) hospitalizations in high-risk symptomatic patients, regardless of ejection fraction. The objectives of this study were to simulate the estimated clinical and economic impact in Germany of generalized use of this PA pressure monitoring system considering reductions of HF hospitalizations and the improvement in Quality of Life.
Materials And Methods:
Based on the Prospective Health Technology Assessment approach, we simulated the potential of the widespread application of PA pressure monitoring on the German healthcare system for the period 2009-2021.
Results:
This healthcare economic simulation formulated input assumptions based on results from the CHAMPION Trial, a multicenter, prospective, randomized controlled U.S. trial that demonstrated a 37% reduction of hospitalizations in persistently symptomatic previous HF patients. Based on these results, an estimated 114,800 hospitalizations would expected to be avoided. This effect would potentially save an estimated €522 million, an equivalent of $575 million, during the entire simulation period.
Conclusion:
This healthcare economic modeling of the PA pressure monitoring system's impact demonstrates substantial clinical and economic benefits in the German healthcare system.
More Related Videos
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
08:12Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Holter Monitor: 24-Hour Monitoring
Heart Failure VI: Adjunct Therapies