Related Experiment Video
Updated: Mar 19, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Air-Q laryngeal airway for rescue and tracheal intubation
Ayman Ads1, Frederic Auerbach1, Kelly Ryan2
1Department of Anesthesiology, Rush University Medical Center, Pittsburgh, PA.
Abstract:
We report the successful use of the Air-Q laryngeal airway (Air-Q LA) as a ventilatory device and a conduit for tracheal intubation to rescue the airway in a patient with difficult airway and tracheal stenosis. This is the first case report of the device to secure the airway after two episodes of hypoxemia in the operating room and intensive care unit. Consent for submission of this case report was obtained from our institution's human studies institutional review board given that the patient died a few months after his discharge from the hospital before his personal consent could be obtained and before preparation of this report. All personal identifiers that could lead to his identification have been removed from this report. A 59-year-old man was scheduled for a flexible and rigid bronchoscopy with possible laser excision of tracheal stenosis. He had a history of hypertension, atrial fibrillation, and diabetes. Assessment of airway revealed a thyromental distance of 6.5 cm, Mallampati class II, and body weight of 110 kg. He had hoarseness and audible inspiratory/expiratory stridor with Spo2 90% breathing room air. After induction and muscle relaxation, tracheal intubation and flexible bronchoscopy were achieved without incident. The patient was then extubated and a rigid bronchoscopy was attempted but failed with Spo2 dropping to 92%; rocuronium 60 mg was given, and reintubation was accomplished with a 7.5-mm endotracheal tube. A second rigid bronchoscopy attempt failed, with Spo2 dropping to 63%. Subsequent direct laryngoscopy revealed a bloody hypopharynx. A size 4.5 Air-Q LA was placed successfully and confirmed with capnography, and Spo2 returned to 100%. The airway was suctioned through the Air-Q LA device, and the airway was secured using a fiberoptic bronchoscope to place an endotracheal tube of 7.5-mm internal diameter. The case was canceled because of edema of the upper airway from multiple attempts with rigid bronchoscopy. The patient was transported to the surgical intensive care unit (SICU). During day 2 of his SICU stay, he accidentally self-extubated and Spo2 dropped to 20% prompting a code blue call. A size 4.5 Air-Q LA was successfully placed by the anesthesia resident on call and Spo2 rose to 100%. The airway was then secured after suction of bloody secretions and visualization of edematous vocal cords with a fiberoptic bronchoscope and proper placement of an endotracheal tube of 7.5-mm internal diameter, confirmed by capnography. During the short period of hypoxemia, the patient's blood pressure, heart rate, and electrocardiogram had remained stable. On the sixth day of SICU admission, he underwent surgical tracheostomy and laser excision of a stenotic tracheal lesion, returned to the SICU, was weaned off mechanical ventilation, and discharged 2 weeks later to a rehabilitation center with stable ventilatory capabilities. This case demonstrates successful use of the Air-Q LA in the emergency loss of airway scenario as a ventilatory device and as a conduit for endotracheal intubation when fiberoptic bronchoscopy alone may be difficult and hazardous. This case suggests the need for further evaluation of the impact of the Air-Q LA on outcomes when used as a rescue device and conduit for tracheal intubation in patient with disease activity.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...