Related Experiment Video
Updated: Mar 19, 2026

A Sensitive Visual Method for the Detection of Hydrogen Sulfide Producing Bacteria
Published on: June 27, 2022
Visualization of exhaled hydrogen sulphide on test paper with an ultrasensitive and time-gated luminescent probe
Ruilong Zhang1, Shijiang Liu2, Jianping Wang3
1Center for Excellence in Nanoscience, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, Anhui 230031, China. bhliu@iim.ac.cn zpzhang@iim.ac.cn and Department of Chemistry, University of Science and Technology of China, Hefei, Anhui 230026, China and School of Chemistry and Chemical Engineering, Anhui University, Hefei, 230601, China.
Abstract:
Luminescent chemosensors for hydrogen sulphide (H2S) are of great interest because of the close association of H2S with our health. However, current probes for H2S detection have problems such as low sensitivity/selectivity, poor aqueous-solubility or interference from background fluorescence. This study reports an ultrasensitive and time-gated "switch on" probe for detection of H2S, and its application in test paper for visualization of exhaled H2S. The complex probe is synthesized with a luminescent Tb(3+) centre and three ligands of azido (-N3) substituted pyridine-2,6-dicarboxylic acid, giving the probe high hydrophilicity and relatively fast reaction dynamics with H2S because there are three -N3 groups in each molecule. The introduced -N3 group as a strong electron-withdrawing moiety effectively changes the energy level of ligand via intramolecular charge transfer (ICT), and thus breaks the energy transferring from ligand to lanthanide ion, resulting in quenching of Tb(3+) luminescence. On addition of H2S, the -N3 group can be reduced to an amine group to break the process of ICT, and the luminescence of Tb(3+) is recovered at a nanomolar sensitivity level. With a long lifetime of luminescence of Tb(3+) centre (1.9 ms), use of a time-gated technique effectively eliminates the background fluorescence by delaying fluorescence collection for 0.1 ms. The test paper imprinted by the complex probe ink can visualize clearly the trace H2S gas exhaled by mice.
More Related Videos
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
10:01Protein Film Infrared Electrochemistry Demonstrated for Study of H2 Oxidation by a [NiFe] Hydrogenase
Published on: December 4, 2017