Related Experiment Video
Updated: Mar 19, 2026

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Physicians' Perceptions of Radiation Dose Quantity Depend on the Language in Which It Is Expressed
Anand K Narayan1, Daniel Brotman1, Leonard S Feldman1
1Johns Hopkins Hospital, Baltimore, Maryland.
Purpose:
Radiation dose information is increasingly requested by nonradiology providers, but there are no standard methods for communicating dose. The aim of this study was to compare physicians' perceptions of the amount of radiation associated with similar dose quantities expressed using different dose terms to evaluate the impact of word choice on physicians' understanding of radiation dose.
Methods:
Internal medicine and pediatric residents were surveyed online for 42 days. After obtaining demographics and training levels, respondents were asked to rank five different radiation dose quantities, each corresponding to one of the five ACR relative radiation levels (RRLs) expressed using different dose terms. Respondents ranked the choices from least to greatest (ie, from 1 to 5) or indicated if all five were equal. For the final question, the same dose quantity was expressed five different ways.
Results:
Fifty-one medicine and 45 pediatric residents responded (a 44% response rate). Mean differences in rankings were as follows: for chest x-rays, 0.109 (95% confidence interval [CI], -0.018 to 0.236); for cross-country flights, 0.462 (95% CI, 0.338 to 0.585); for natural background radiation, -0.672 (95% CI, -0.793 to -0.551); for cancer risk, -0.294 (95% CI, -0.409 to -0.178); and for ACR RRL, 0.239 (95% CI, 0.148 to 0.329). Statistically significant differences were found in the distributions of rankings (P < .001) and percentage of correct rankings across each radiation dose term (P < .001), with the ACR RRL having the highest percentage of correct rankings (61.2%).
Conclusions:
Adult and pediatric physicians consistently over- or underestimated radiation dose quantities using different terms to express radiation dose. These results suggest that radiation dose information should be communicated using standard terminology such as the ACR RRL scale to foster consistency and improve the accuracy of physicians' radiation risk perceptions.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Biological Effects of Radiation
Absorption of Radiation
Dosage Regimen Designs: Nomograms and Tabulations
Dose Response Curve: Conventional Versus Nonmonotonic
X-ray Imaging
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...