Related Experiment Video
Updated: Mar 19, 2026

3D Cine Magnetic Resonance Imaging of Respiratory Motion in Mechanically Ventilated Mice and Rats
Published on: September 19, 2025
Evaluation of Bag-Valve-Mask Ventilation in Manikin Studies: What Are the Current Limitations?
A Khoury1, F S Sall1, A De Luca1
1Department of Emergency Medicine & Critical Care, University of Franche-Comté, Medical Centre, 25000 Besançon, France; Clinical Investigation Centre, INSERM CIC-1431, University of Franche-Comté, Medical Centre, 25000 Besançon, France.
Abstract:
Introduction. Manikin-based studies for evaluation of ventilation performance show high heterogeneity in the analysis and experimental methods used as we pointed out in previous studies. In this work, we aim to evaluate these potential limitations and propose a new analysis methodology to reliably assess ventilation performance. Methods. One hundred forty healthcare providers were selected to ventilate a manikin with two adult self-inflating bags in random order. Ventilation parameters were analysed using different published analysis methods compared to ours. Results. Using different methods impacts the evaluation of ventilation efficiency which ranges from 0% to 45.71%. Our new method proved relevant and showed that all professionals tend to cause hyperventilation and revealed a significant relationship between professional category, grip strength of the hand keeping the mask, and ventilation performance (p = 0.0049 and p = 0.0297, resp.). Conclusion. Using adequate analysis methods is crucial to avoid many biases. Extrapolations to humans still have to be taken with caution as many factors impact the evaluation of ventilation performance. Healthcare professionals tend to cause hyperventilation with current devices. We believe this problem could be prevented by implementing monitoring tools in order to give direct feedback to healthcare professionals regarding ventilation efficiency and ventilatory parameter values.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...

