High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
Published on: December 22, 2015
15.8K
Precise Determination of Brillouin Scattering Spectrum Using a Virtually Imaged Phase Array (VIPA) Spectrometer and
Zhaokai Meng1, Vladislav V Yakovlev2
1Texas A&M University, Biomedical Engineering, College Station, TX, USA.
Applied Spectroscopy
|June 15, 2016
Summary
This study introduces a new method for analyzing Brillouin spectroscopy data, improving the accuracy of viscoelastic property measurements in turbid materials by accounting for absorption cell effects.
Area of Science:
- Optical Physics
- Materials Science
- Spectroscopy
Background:
- Brillouin spectroscopy offers noninvasive assessment of viscoelastic properties.
- Atomic-molecular absorption cells enable Brillouin spectroscopy in turbid samples by filtering strong elastic scattering.
- Existing methods struggle with altered Brillouin line shapes caused by absorption cells, hindering precise shift determination.
Purpose of the Study:
- To develop a simple and accurate method for analyzing Brillouin spectra acquired using atomic-molecular absorption cells.
- To address the challenge of altered Brillouin line shapes and improve the precision of spectral shift measurements.
- To validate the proposed analysis method with experimental data.
Main Methods:
- A customized least-square fitting algorithm was developed for Brillouin spectrum analysis.
- The method explicitly incorporates the absorption spectrum induced by the atomic-molecular cell.
- Experimental spectroscopic data from pure water at various temperatures were processed.
Main Results:
- The developed method effectively analyzes Brillouin spectra, considering the absorption cell's spectral signature.
- Precise determination of Brillouin shifts was achieved, overcoming limitations of previous methods.
- Experimental validation demonstrated the capability of the method, achieving an accuracy of ±1 MHz for spectral line shift measurements.
Conclusions:
- The proposed least-square fitting method provides a simple and accurate approach for analyzing Brillouin spectra obtained with atomic-molecular absorption cells.
- This advancement enhances the noninvasive assessment of viscoelastic properties in turbid materials.
- The method's demonstrated accuracy opens avenues for more reliable material characterization using Brillouin spectroscopy.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
1.6K
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
1.6K
UV–Vis Spectrometers
4.4K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
4.4K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
939
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
939
IR Spectrometers
3.3K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
3.3K
UV–Vis Spectroscopy: Beer–Lambert Law
7.9K
The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The modern...
7.9K
Atomic Absorption Spectroscopy: Instrumentation
2.0K
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
2.0K