Related Experiment Video
Updated: Mar 19, 2026

Author Spotlight: Developing a Bedside Protocol for Kidney and Genitourinary Ultrasonography
Published on: June 21, 2024
Spectrum, Applicability and Diagnostic Capacity of Contrast-Enhanced Ultrasound in Pediatric Patients and Young
F Knieling1, D Strobel2, O Rompel3
1Department of Pediatrics, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany.
Insights
Intravenous contrast-enhanced ultrasound imaging (CEUS) is safe and effective for pediatric patients. This diagnostic tool offers significant advantages over other imaging methods for children and young adults.
Area of Science:
- Pediatric Radiology
- Medical Imaging
- Diagnostic Ultrasound
Background:
- Contrast-enhanced ultrasound imaging (CEUS) is an established diagnostic modality.
- Its application and diagnostic capacity in pediatric populations require further investigation.
- Evaluating CEUS in children and young adults is crucial for optimizing imaging protocols.
Purpose of the Study:
- To assess the spectrum, applicability, and diagnostic accuracy of CEUS in pediatric patients.
- To document ultrasound contrast agent (UCA) dosage and potential side effects.
- To compare CEUS findings with gold standards like histology, surgery, and reference imaging.
Main Methods:
- Retrospective analysis of 40 pediatric patients (0–26 years) undergoing 55 CEUS investigations.
- Administration of 79 IV UCA applications, with documentation of dosage and adverse events.
- CEUS evaluation of liver, spleen, kidney, and testis, with comparison to histology, surgery, or reference imaging.
Main Results:
- Low incidence of adverse effects (2.5%) with CEUS in pediatric patients.
- High diagnostic agreement between CEUS and gold standards (32/34 investigations).
- Excellent performance in liver lesion characterization (100% specificity, 82% sensitivity) and accurate diagnosis of splenic/renal lesions.
Conclusions:
- CEUS is a well-tolerated and safe imaging modality for pediatric care.
- CEUS demonstrates diagnostic equivalence and offers significant advantages over conventional imaging techniques in pediatric populations.
- The findings support the broader implementation of CEUS in pediatric diagnostics.
Abstract:
Purpose: To investigate the spectrum, applicability and diagnostic capacity of intravenous contrast-enhanced ultrasound imaging (CEUS) in a pediatric population. Materials and Methods: From 08/2005 to 11/2015, n = 40 pediatric patients and young adults from 0 - 26 years (Ø 11.4 ± 7.5) and 3.0 - 85.3 kg (Ø 40.8 ± 25.6) with n = 55 investigations received n = 79 IV applications of ultrasound contrast agent (UCA). UCA dose and side effects were documented. Scanned organs were the liver (n = 42), spleen (n = 9), kidney (n = 3), and testis (n = 1). Histology, surgery or reference imaging was compared to CEUS and clinical follow-up. Results: The UCA dose < 20 kg was 0.4 ± 0.3 ml, (0.05 ± 0.02 ml/kg) and > 20 kg was 1.0 ± 0.4 ml (p< 0.0001) (0.02 ± 0.01 ml/kg, p< 0.0001). Adverse effects occurred in 2/79 applications (2.5 %). Agreement CEUS/gold standard resulted in 32/34 investigations. For liver diagnostics (gold standard: MRI, CT, histology, serology), n = 11 malignant and n = 15 benign focal liver lesions were included. The specificity was 100 % (95 % CI: 0.77 - 1.00), the sensitivity was 82 % (95 % CI: 0.48 - 0.98), the positive predictive value was 100 % (95 % CI: 0.69 - 1.00) and the negative predictive value was 88 % (95 % CI: 0.62 - 0.98, p< 0.0001). In n = 2 reference imaging misdiagnosed and CEUS was in accordance with clinical follow-up. All splenic/renal lesions were diagnosed correctly. In n = 1 an insufficient testicular perfusion was ruled out. The observation time was 30.4 ± 30.5 months. Conclusion: CEUS is a well-tolerated and diagnostically equivalent modality in pediatric care, providing fundamental advantages compared to currently approved imaging modalities for these age groups.
Related Concept Videos
Imaging Studies III: Computed Tomography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT