Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

7.5K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
7.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A thermosensitive hydrogel delivery system incorporating wogonin-treated mesenchymal stromal cell (MSC)-derived exosomes alleviates osteoarthritis.

Journal of biological engineering·2026
Same author

Flexible Porous Pomelo Pith Derived Janus Liquid Metal and Adhesive Hydrogel Hybrid Electronic Skins.

Smart medicine·2026
Same author

Deep Learning Based on B-Mode and Color Doppler Ultrasound for Differentiation of Primary Thyroid Lymphoma and Hashimoto's Thyroiditis: A Retrospective Single-Center Study.

Diagnostics (Basel, Switzerland)·2026
Same author

Rectal endometriosis mimicking rectal cancer.

Gastroenterologia y hepatologia·2026
Same author

Developing an Open-Source Framework for the Quantitative Simulation of Blood Flow and Tissue Motion for Ultrafast Doppler Ultrasound.

Ultrasound in medicine & biology·2026
Same author

Sodium Ascorbate-Accelerated Gelling Hydrogels With Rapid Self-Mineralized Capacity for Chronic Wounds.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026

Related Experiment Video

Updated: Nov 10, 2025

Switchable Acoustic and Optical Resolution Photoacoustic Microscopy for In Vivo Small-animal Blood Vasculature Imaging
10:17

Switchable Acoustic and Optical Resolution Photoacoustic Microscopy for In Vivo Small-animal Blood Vasculature Imaging

Published on: June 26, 2017

12.2K

Slip-ring-based multi-transducer photoacoustic tomography system.

Zijian Deng, Wenzhao Li, Changhui Li

    Optics Letters
    |June 16, 2016
    PubMed
    Summary

    This study introduces a cost-effective photoacoustic tomography (PAT) system using an electrical slip ring. The novel design enhances imaging speed and versatility for simultaneous, continuous multi-transducer imaging.

    Area of Science:

    • Biomedical Imaging
    • Optical Physics
    • Medical Technology

    Background:

    • Transducer array-based photoacoustic tomography (PAT) systems offer fast imaging but are limited by high cost and complexity.
    • Existing PAT systems face challenges in simultaneous and continuous multi-transducer operation.

    Purpose of the Study:

    • To develop a novel, cost-effective photoacoustic tomography (PAT) system.
    • To improve imaging speed and versatility in PAT systems.
    • To enable simultaneous and continuous imaging using multiple transducers.

    Main Methods:

    • Integration of an electrical slip ring into a photoacoustic tomography (PAT) system.
    • Utilization of multiple transducers for simultaneous and continuous data acquisition.
    • System performance evaluation using phantom and in vivo animal models.

    More Related Videos

    Photoacoustic Cystography
    09:49

    Photoacoustic Cystography

    Published on: June 11, 2013

    13.5K
    Three-dimensional Optical-resolution Photoacoustic Microscopy
    08:31

    Three-dimensional Optical-resolution Photoacoustic Microscopy

    Published on: May 3, 2011

    18.5K

    Related Experiment Videos

    Last Updated: Nov 10, 2025

    Switchable Acoustic and Optical Resolution Photoacoustic Microscopy for In Vivo Small-animal Blood Vasculature Imaging
    10:17

    Switchable Acoustic and Optical Resolution Photoacoustic Microscopy for In Vivo Small-animal Blood Vasculature Imaging

    Published on: June 26, 2017

    12.2K
    Photoacoustic Cystography
    09:49

    Photoacoustic Cystography

    Published on: June 11, 2013

    13.5K
    Three-dimensional Optical-resolution Photoacoustic Microscopy
    08:31

    Three-dimensional Optical-resolution Photoacoustic Microscopy

    Published on: May 3, 2011

    18.5K

    Main Results:

    • Successfully developed a PAT system incorporating an electrical slip ring, reducing cost and complexity.
    • Demonstrated simultaneous and continuous imaging capabilities with multiple transducers.
    • Validated the system's performance in both phantom and in vivo experiments.

    Conclusions:

    • The novel electrical slip ring-based PAT system offers a viable solution for cost-effective and versatile biomedical imaging.
    • This approach enhances the practicality of PAT for various applications requiring simultaneous and continuous imaging.
    • The developed system shows promise for advancing photoacoustic tomography implementations.