Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Peripheral Venous Pressure as an Indicator of Preload Responsiveness During Volume Resuscitation from Hemorrhage
Michael Kinsky1, Nicole Ribeiro, Maxime Cannesson
1From the *Department of Anesthesiology, The University of Texas Medical Branch at Galveston, Galveston, Texas; †Department of Anesthesiology and Perioperative Medicine, David Geffen School of Medicine at UCLA, Los Angeles, California; ‡Department of Respiratory Care and §Department of Biostatistics, The University of Texas Medical Branch at Galveston, Galveston, Texas; and ‖Baylor Scott & White Healthcare, Texas A&M University School of Medicine, Temple, Texas.
Background:
Fluid resuscitation of hypovolemia presumes that peripheral venous pressure (PVP) increases more than right atrial pressure (RAP), so the net pressure gradient for venous return (PVP-RAP) rises. However, the heart and peripheral venous system function under different compliances that could affect their respective pressures during fluid infusion. In a porcine model of hemorrhage resuscitation, we examined whether RAP increases more than PVP, thereby reducing the venous return pressure gradient and blood flow.
Methods:
Anesthetized pigs (n = 8) were bled to a mean arterial blood pressure of 40 mm Hg and resuscitated with stored blood and albumin for pulmonary artery occlusion pressures (PAOPs) of 5, 10, 15, and 20 mm Hg. Venous pressures, inferior vena cava blood flow (ultrasonic flowprobe), and left ventricular diastolic compliance (Doppler echocardiography) were measured. Stroke volume variability was calculated.
Results:
With volume resuscitation, the slope of RAP exceeded PVP (P ≤ 0.0001) when PAOP is 10 to 20 mm Hg, causing the pressure gradient for venous return to progressively decrease. Inferior vena cava blood flow did not further increase after PAOP > 10 mm Hg. The E/e' ratio increased (P = 0.001) during resuscitation indicating reduced diastolic compliance. A significant curvilinear relationship was found between PVP and stroke volume variability (R = 0.62; P < 0.001), where fluid responders had PVP < 15 mm Hg.
Conclusions:
Fluid resuscitation above a PAOP 10 mm Hg reduces myocardial compliance and reduces the venous return pressure gradient. The hemodynamic response to fluid resuscitation becomes limited by diastolic properties of the heart. PVP measurement during hemorrhage resuscitation may predict fluid responsiveness and nonresponsiveness.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Veins as Blood Reservoirs
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...