Evaluation of thyroid calcification using computed radiography with image plate.

H Fukatsu1, N Makino, Y Kodama

  • 1Department of Radiology, Nagoya University School of Medicine, Aichi, Japan.

European Journal of Radiology
|February 1, 1989
PubMed
Summary

Computed Radiography (CR) systems offer comparable or superior detection of thyroid calcification compared to traditional screen-film methods. This imaging technology achieved a 77.1% accuracy in distinguishing between malignant and benign thyroid conditions.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Endoscopic evaluation of food bolus formation and its relationship with the number of chewing cycles.

Journal of oral rehabilitation·2015
Same author

Gastrointestinal: esophageal metastasis from hepatocellular carcinoma.

Journal of gastroenterology and hepatology·2012
Same author

Pancreatic cancer metastasis to the rectum detected on colonoscopy.

Endoscopy·2009
Same author

Cognitive impairments in multiple system atrophy: MSA-C vs MSA-P.

Neurology·2008
Same author

An iatrogenic hepatic subcapsular biloma successfully treated by percutaneous drainage and endoscopic biliary stenting.

Endoscopy·2008
Same author

Imaging of endolymphatic and perilymphatic fluid at 3T after intratympanic administration of gadolinium-diethylene-triamine pentaacetic acid.

AJNR. American journal of neuroradiology·2008

Area of Science:

  • Medical Imaging
  • Radiography
  • Diagnostic Radiology

Background:

  • Soft x-ray roentgenography is crucial for diagnosing thyroid conditions.
  • Evaluating advanced imaging systems is essential for improving diagnostic accuracy.
  • Computed Radiography (CR) offers potential advantages over conventional screen-film systems.

Purpose of the Study:

  • To assess the diagnostic efficacy of lateral magnification soft x-ray roentgenography utilizing a Computed Radiography (CR) system.
  • To compare the performance of CR systems against traditional screen-film systems for detecting thyroid calcification.
  • To determine the accuracy of CR systems in differentiating malignant from benign thyroid lesions.

Main Methods:

  • Lateral magnification soft x-ray roentgenography was performed using a CR system.

Related Experiment Videos

  • Receiver Operating Characteristic (ROC) curve analysis was employed to evaluate detection performance.
  • Diagnostic accuracy for malignant/benign classification was calculated based on established criteria.
  • Main Results:

    • ROC curve analysis indicated that the CR system demonstrated comparable or superior performance to screen-film systems in detecting thyroid calcification.
    • The CR system achieved a diagnostic accuracy rate of 77.1% for differentiating between malignant and benign thyroid conditions.
    • No significant degradation in image quality or diagnostic capability was observed with the CR system.

    Conclusions:

    • Computed Radiography (CR) systems are a viable and effective tool for lateral magnification soft x-ray roentgenography of the thyroid.
    • CR systems provide diagnostic performance equal to or better than screen-film systems for thyroid calcification detection.
    • The CR system's accuracy in malignant/benign diagnosis supports its clinical utility in thyroid imaging.