Related Experiment Video
Updated: Mar 19, 2026

Preparation of a Corannulene-functionalized Hexahelicene by CopperI-catalyzed Alkyne-azide Cycloaddition of Nonplanar Polyaromatic Units
Published on: September 18, 2016
[Single-handed helical framework material [{Cu(sala)}n] incorporated peramylated β-cyclodextrin for improving gas
Abstract:
Metal-organic frameworks (MOFs) as a new generation of functional molecular materials, have broad application prospects in enantioselective catalysis and chiral separation areas due to their unusual properties, such as high surface area, rich topologies, permanent microporous, availability of outer-surface modification and so on. A single-handed helical three-dimensional metal-organic framework material [{Cu(sala)}n] (H2sala=N-(2-hydroxybenzyl)-L-alanine) was incorporated with peramylated β-cyclodextrin for the preparation of novel capillary gas chromatography stationary phase. To investigate whether the use of a chiral MOF can enhance enantioseparation on peramylated β-cyclodextrin, three chiral columns were fabricated using different stationary phases for comparison, including column A ([{Cu (sala)}n]), column B (peramylated β-cyclodextrin) and column C ([{Cu(sala)}n]+peramylated β-cyclodextrin). The results of comparing the resolving abilities of the three columns for the same chiral compounds demonstrated that column C showed better enantioselectivity and higher resolution. The use of MOF [{Cu(sala)}n] can improve enantioseparation on peramylated β-cyclodextrin.
More Related Videos
09:22Self-assembling Morphologies Obtained from Helical Polycarbodiimide Copolymers and Their Triazole Derivatives
Published on: February 7, 2017
09:45Accessing Valuable Ligand Supports for Transition Metals: A Modified, Intermediate Scale Preparation of 1,2,3,4,5-Pentamethylcyclopentadiene
Published on: March 20, 2017
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Stability of Substituted Cyclohexanes
The two chair conformations of cyclohexanes undergo rapid interconversion at room temperature. Both forms have identical energies and stabilities, each comprising equal amounts of the equilibrium mixture. Replacing a hydrogen atom with a functional group makes the two conformations energetically non-equivalent.
For example, in...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Prochirality