Related Experiment Video
Updated: Mar 19, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Pulse Oximeter-Derived Pleth Variability Index is a Reliable Indicator of Cardiac Preload in Patients Undergoing
H-C Lee1, Y-F Tsai1, H-I Tsai1
1Department of Anesthesiology, Chang Gung Memorial Hospital, Taoyuan, Taiwan, ROC; College of Medicine, Chang Gung University, Taoyuan, Taiwan, ROC; Graduate Institute of Clinical Medical Sciences, Chang Gung University, Taoyuan, Taiwan, ROC.
Background:
Accurate estimation of cardiac preload during liver transplantation is essential. The right ventricular end-diastolic volume index (RVEDVI) is recognized as a good preload indicator in patients undergoing liver transplantation. Recently, dynamic variation parameters including pleth variability index (PVI) have been used as predictors of fluid responsiveness. However, the correlation between PVI and preload status has not been well studied. We evaluated the relationship between PVI and RVEDVI during liver transplantation.
Methods:
Eighteen patients undergoing liver transplantation were enrolled in this study. Data of hemodynamic parameters including PVI derived by Masimo Rainbow SET Pulse CO-Oximeter, central venous pressure (CVP), pulmonary arterial occlusion pressure (PAOP), and RVEDI were obtained at 10 defined time points throughout liver transplantation. The correlation between RVEDVI and CVP, PAOP, and PVI was analyzed using Spearman rank test. We also investigated the ability of PVI to accurately differentiate RVEDVI <123 or >142 mL/m(2) using receiver operating characteristic (ROC) analysis.
Results:
There was fair to good correlation between PVI and RVEDVI (correlation coefficient = -0.492, P < .001). The correlation coefficient between CVP, PAOP, and RVEDVI was 0.345 and 0.463, respectively. A 13.5% cutoff value of PVI estimated the RVEDVI <123 mL/m(2) (area under the curve [AUC] = 0.762). A 12.5% cutoff value of PVI estimated the RVEDVI >142 mL/m(2) (AUC = 0.745).
Conclusions:
PVI presented as a reliable estimate of preload status and may be a useful predictor of fluid responsiveness in patients undergoing liver transplantation.
More Related Videos
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.