Related Concept Videos

Errors occurring during blood pressure monitoring01:25

Errors occurring during blood pressure monitoring

1.7K
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
1.7K
Holter Monitor: 24-Hour Monitoring01:23

Holter Monitor: 24-Hour Monitoring

3.9K
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
3.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Energy requirements: the case for the factorial model.

The American journal of clinical nutrition·2026
Same author

Assessing the impact of combined nutritional and physical activity interventions for patients with atrial fibrillation who are overweight: a systematic review protocol.

BMJ open·2026
Same author

Association between intrinsic capacity and disability before death among older adults: a decedent cohort study.

The lancet. Healthy longevity·2026
Same author

DNA methylation-mediated memory of obesity in CD4 T lymphocytes perpetuates immune dysregulation.

EMBO reports·2026
Same author

How long should washout be to reliably measure hepatic de novo lipogenesis using deuterated water? Exploratory analysis from a randomized crossover trial.

American journal of physiology. Endocrinology and metabolism·2026
Same author

The feasibility of implementing and evaluating individualised digital prehabilitation prior to major elective surgery in adults aged ≥ 50 years: the PreActiv intervention.

Perioperative medicine (London, England)·2026

Related Experiment Video

Updated: Mar 19, 2026

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
05:51

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health

Published on: February 21, 2025

1.5K

Feedback from physical activity monitors is not compatible with current recommendations: A recalibration study.

Dylan Thompson1, Alan M Batterham2, Oliver J Peacock1

  • 1Department for Health, University of Bath, Bath BA2 7AY, UK.

Preventive Medicine
|June 23, 2016
PubMed
Summary

Wearable device feedback on physical activity is currently incompatible with health guidelines. Recalibrating recommendations to include lifestyle activity suggests ~1000 minutes of moderate-to-vigorous activity weekly is needed.

Keywords:
ExercisePhysical activity energy expenditurePhysical activity monitoringPhysical activity recommendationsPhysical activity status

More Related Videos

Visualization of Intensity Levels to Reduce the Gap Between Self-Reported and Directly Measured Physical Activity
05:59

Visualization of Intensity Levels to Reduce the Gap Between Self-Reported and Directly Measured Physical Activity

Published on: March 7, 2019

7.3K
A Method for Quantifying Upper Limb Performance in Daily Life Using Accelerometers
07:24

A Method for Quantifying Upper Limb Performance in Daily Life Using Accelerometers

Published on: April 21, 2017

13.2K

Related Experiment Videos

Last Updated: Mar 19, 2026

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
05:51

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health

Published on: February 21, 2025

1.5K
Visualization of Intensity Levels to Reduce the Gap Between Self-Reported and Directly Measured Physical Activity
05:59

Visualization of Intensity Levels to Reduce the Gap Between Self-Reported and Directly Measured Physical Activity

Published on: March 7, 2019

7.3K
A Method for Quantifying Upper Limb Performance in Daily Life Using Accelerometers
07:24

A Method for Quantifying Upper Limb Performance in Daily Life Using Accelerometers

Published on: April 21, 2017

13.2K

Area of Science:

  • Public Health
  • Exercise Science
  • Biomedical Engineering

Background:

  • Wearable devices for self-monitoring physical activity are widely used for chronic disease prevention.
  • Current physical activity guidelines are difficult to reconcile with device feedback due to recommendations exceeding normal lifestyle activity.
  • This discrepancy can lead to misinterpretation of activity levels by users.

Purpose of the Study:

  • To recalibrate feedback from wearable devices to align with established physical activity recommendations.
  • To determine the actual volume of moderate-to-vigorous physical activity (MVPA) needed to meet public health guidelines when accounting for lifestyle activity.
  • To address the incompatibility between self-monitoring device data and current exercise targets.

Main Methods:

  • Pooled data from four studies (2006-2014) involving 305 participants (patients and community volunteers).
  • Utilized sophisticated measures of physical activity and 10-year cardiovascular disease and type 2 diabetes risk assessment.
  • Determined MVPA corresponding to a Physical Activity Level (PAL) of 1.75, based on FAO/WHO/UNU guidance.

Main Results:

  • At the UK median PAL, total weekly MVPA was approximately 735 minutes (~11% of waking time).
  • Achieving standardized FAO/WHO/UNU guidance requires an estimated 1000 minutes of MVPA per week (~15% of waking time).
  • This represents a ~4% increase in MVPA compared to the median lifestyle activity levels.

Conclusions:

  • Feedback from current wearable devices is incompatible with existing physical activity recommendations without adjustment.
  • Users may erroneously believe they are exceeding guidelines significantly due to the discrepancy.
  • A revised target of ~1000 minutes of MVPA per week is proposed for self-monitoring to accurately reflect public health goals.