Related Experiment Video
Updated: Mar 19, 2026

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Calculating annoyance: an option to proof efficacy in ENT treatment of snoring?
René Fischer1, Thomas S Kuehnel2, Anne-Kathrin Merz3
1Department of Otorhinolaryngology, University of Regensburg, 93042, Regensburg, Germany. rene.fischer@klinik.uni-regensburg.de.
Abstract:
To develop and validate an objective method for calculating the annoyance caused by snoring sounds. 53 subjects assessed 50 different snoring and breath sounds on a visual analog scale for level of annoyance. A linear regression analysis was used to correlate these subjective assessments with objectively calculated psychoacoustic parameters (loudness, roughness, sharpness, and fluctuation strength, calculating the maximum, mean, and 5th percentile in each case). The quality of the resulting formula was checked, and additional validation was performed using subjective assessments of 60 new snoring and breath sounds by 52 new subjects. Receiver operating characteristic (ROC) analysis was used to scale the annoyance ranges obtained with the formula. A score consisting of the 5th percentile of loudness and the mean of roughness was developed. The formula displays high goodness of fit (R 2 = 0.91) and quality. In the validation phase, a highly significant correlation (r s = 0.95; p < 0.01) was obtained between the scores calculated with the formula and the subjective assessments. ROC analysis was able to define the annoyance ranges with a discriminatory power between 52 and 73 % (optimum sensitivity/specificity). The subjective assessments made by the participants were distinctly scaled and were reflected in a psychophysical algorithm. In the setting of polygraphy and polysomnography, this means that a reliable annoyance score that is not dependent on the bed partner can be obtained to establish the indication for anti-snoring treatments and to review their utility.
More Related Videos
Related Concept Videos
Drug Delivery: Enteral Route
Sleep Apnea
The condition is more prevalent among...
Treatment for Pulmonary Arterial Hypertension: Endothelin Receptor Antagonists
ETs are synthesized through a complex sequence of enzymatic steps, primarily involving an enzyme referred to as endothelin-converting enzyme...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Chronic Pharyngitis
Etiology
It often arises from persistent viral or bacterial infections affecting sinuses and tonsils.
Additional contributing factors include inadequate dental hygiene, mouth breathing, recurring tonsillitis, allergic rhinitis, laryngopharyngeal reflux, and exposure to smoke, chemicals, and other environmental pollutants. Allergic reactions to pollen, mold, and pet dander, chronic cough, excessive voice usage,...
Tonsillitis II: Management

