Related Experiment Video
Updated: Mar 19, 2026

Training Rats to Voluntarily Dive Underwater: Investigations of the Mammalian Diving Response
Published on: November 12, 2014
A comparison of simple reaction time, visual discrimination and critical flicker fusion frequency in professional
Janne Tikkinen1,2, Tomi Wuorimaa3, Martti A Siimes3
1Diving Medical Centre, Centre for Military Medicine, SLK, PL 5, FIN-02471, Upinniemi, Finland, janne.tikkinen@mil.fi.
Introduction:
Inert gas narcosis (IGN) impairs cognitive performance and some divers are more susceptible to IGN than others. We compared the sensitivity of two reaction time tests to detect changes in performance at pressure and compared these results with critical flicker fusion frequency (CFF) changes at the same ambient pressures.
Methods:
The study assessed simple reaction time (RT), mean time correct of the discrimination reaction time (MTC) and CFF in 30 professional divers breathing air at 101 kPa and 608 kPa in a hyperbaric chamber.
Results:
RT and MTC increased at 608 kPa by 5.1 ± 9.4% (P = 0.04) and 7.3 ± 12.3% (P = 0.01) respectively. RT decreased to pre-compression level after decompression and MTC decreased to a level lower than pre-compression (P < 0.001) values. CFF increased by 2.5 ± 2.8% (P < 0.001) at 608 kPa. CFF decreased to pre-compression level after decompression. An increase in CFF was inversely correlated with a decrease in RT (r = 0.38, P = 0.04) and in MTC (r = 0.43, P = 0.02) at 608 kPa.
Conclusions:
Response speeds of the same subjects were impaired in both reaction time tasks at 608 kPa, whereas CFF increased at depth. An association between changes in response times and changes in CFF suggests that divers susceptible to IGN may also be susceptible to the effects of elevated oxygen partial pressure. If this holds true, the future selection of professional divers could be improved by the use of simple cognitive tests.