The duration of two carbon dioxide absorbents in a closed-circuit rebreather diving system
David Harvey1, Neal W Pollock2,3, Nicholas Gant4
1Department of Anaesthesia, Auckland City Hospital, New Zealand.
Introduction:
Diving rebreathers use canisters containing sodalime preparations to remove carbon dioxide (CO₂) from the expired gas. These preparations have a limited absorptive capacity and therefore may limit dive duration. The Inspiration™ rebreather is designed for use with Sofnolime 797™ but some divers use Spherasorb™ as an alternative. There are no published data comparing the CO2-absorbing efficacy of these sodalime preparations in an Inspiration rebreather.
Methods:
An Inspiration rebreather was operated in a benchtop circuit under conditions simulating work at 6 metabolic equivalents (MET). Ventilation was maintained at 45 L·min⁻¹ (tidal volume 1·5 L; respiratory rate 30 min⁻¹) with CO₂ introduced to the expiratory limb at 2·L·min⁻¹. The PiCO₂ was continuously monitored in the inspiratory limb. The rebreather canister was packed to full volume with either Sofnolime or Spherasorb and 10 trials were conducted (five using each absorbent), in which the circuit was continuously run until the PiCO₂ reached 1 kPa ('breakthrough'). Peak inspiratory and expiratory pressures during tidal ventilation of the circuit were also recorded.
Results:
The mean operating duration to CO₂ breakthrough was 138 ± 4 (SD) minutes for 2.38·kg Spherasorb and 202 ± minutes for 2.64·kg Sofnolime (P < 0.0001). The difference between peak inspiratory and expiratory pressures was 10% less during use of Spherasorb, suggesting lower work of breathing.
Conclusions:
Under conditions simulating work at 6 MET during use of an Inspiration rebreather a canister packed with Spherasorb reached CO₂ breakthrough 32% earlier with 10% less mass than Sofnolime packed to similar volume. Divers cannot alternate between these two preparations and expect the same endurance.
More Related Videos
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Acute Respiratory Failure-III