Evaluating the Effects of Full and Partial Lead Service Line Replacement on Lead Levels in Drinking Water
Benjamin F Trueman1, Eliman Camara1, Graham A Gagnon1
1Civil & Resource Engineering, Dalhousie University , 1360 Barrington Street, Halifax, Nova Scotia B3H 4R2, Canada.
Abstract:
Lead service line replacement (LSLR) is an important strategy for reducing lead exposure via drinking water, but jurisdictional issues can sometimes interfere with full replacement of the lead line. The effects of full and partial LSLR on lead levels were assessed using 5 × 1-L sample profiles collected at more than 100 single-unit residences. Profiles comprised four sequential standing samples (L1-L4) and a free-flowing sample (L5) drawn after a 5 min flush of the outlet. At 45 sites with full lead service lines, 90th percentile lead levels in standing samples ranged from 16.4 to 44.5 μg L(-1) (L1 and L4, respectively). In the free-flowing sample (L5), 90th percentile lead was 9.8 μg L(-1). Within 3 days, full LSLR had reduced L3-L5 lead levels by more than 50%, and within 1 month, lead levels were significantly lower in every liter of the sample profile. Conversely, partial LSLR more than doubled premises plumbing (L1, L2) lead release in the short term and did not reduce L1, L2 lead release in the long term. Even 6 months after partial LSLR, 27% of first-draw lead levels were greater than 15 μg L(-1) (the U.S. EPA action level), compared with 13% pre-replacement.
Related Concept Videos
Quality of Water
Factors Affecting Solubility
Extraction: Advanced Methods
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Microbial Leaching
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...