Short-Term Repeatability of Stabilometric Assessments
Related Experiment Video
Updated: Mar 19, 2026

Author Spotlight: Assessing the Reliability of Doppler Ultrasound in Measuring Leg Blood Flow
Published on: December 15, 2023
Nicola Lovecchio1, Matteo Zago1, Laura Perucca2,3
1a Functional Anatomy Research Center (FARC), Department of Biomedical Sciences for Health, Università degli Studi di Milano , Milano , Italy.
Abstract:
The authors evaluated the short-term (within-day, between-days) repeatability of center of pressure (COP) displacements. COP sway area and speed were obtained in the morning and afternoon of two separate days, both with open (EO) and closed (EC) eyes, in 10 healthy adults. Agreement and variability among conditions were tested by ANOVA and Bland-Altman plots. Mode (EO/EC, area: p = .032; speed: p < .004), and day (day1/day2, area: p = .006; speed: p = .02) showed significant differences. The EC condition and the second test day showed the largest values, with medium-large effect sizes. Time-of-day did not influence COP displacements. Speed had better agreement than area (Bland-Altman plots). COP displacements were well reproducible within-day, but had significant between-days variations. COP assessments should be performed in the same session.