Related Experiment Video
Updated: Mar 19, 2026

Evaluation of Biomaterials for Bladder Augmentation using Cystometric Analyses in Various Rodent Models
Published on: August 9, 2012
Noninvasive Evaluation of Bladder Wall Mechanical Properties as a Function of Filling Volume: Potential Application
Ivan Nenadic1, Lance Mynderse2, Douglas Husmann2
1Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota, United States of America.
Purpose:
We propose a novel method to monitor bladder wall mechanical properties as a function of filling volume, with the potential application to bladder compliance assessment. The proposed ultrasound bladder vibrometry (UBV) method uses ultrasound to excite and track Lamb waves on the bladder wall from which its mechanical properties are derived by fitting measurements to an analytical model. Of particular interest is the shear modulus of bladder wall at different volumes, which we hypothesize, is similar to measuring the compliance characteristics of the bladder.
Materials And Methods:
Three experimental models were used: 1) an ex vivo porcine model where normal and aberrant (stiffened by formalin) bladders underwent evaluation by UBV; 2) an in vivo study to evaluate the performance of UBV on patients with clinically documented compliant and noncompliant bladders undergoing UDS; and 3) a noninvasive UBV protocol to assess bladder compliance using oral hydration and fractionated voiding on three healthy volunteers.
Results:
The ex vivo studies showed a high correlation between the UBV parameters and direct pressure measurement (R2 = 0.84-0.99). A similar correlation was observed for 2 patients with compliant and noncompliant bladders (R2 = 0.89-0.99) undergoing UDS detrusor pressure-volume measurements. The results of UBV on healthy volunteers, performed without catheterization, were comparable to a compliant bladder patient.
Conclusion:
The utility of UBV as a method to monitor changes in bladder wall mechanical properties is validated by the high correlation with pressure measurements in ex vivo and in vivo patient studies. High correlation UBV and UDS in vivo studies demonstrated the potential of UBV as a bladder compliance assessment tool. Results of studies on healthy volunteers with normal bladders demonstrated that UBV could be performed noninvasively. Further studies on a larger cohort are needed to fully validate the use of UBV as a clinical tool for bladder compliance assessment.
More Related Videos
Related Concept Videos
Urodynamic Studies: Uroflowmetry
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies II: Ultrasonography