Lumbar disk compliance and degeneration.

M Brock1, M Lutze

  • 1Department of Neurosurgery, Free University of Berlin, West Germany.

Surgical Neurology
|July 1, 1989
PubMed
Summary

Intradiscal pressure/volume testing correlates with disk degeneration severity. This simple, risk-free procedure should be a standard preoperative diagnostic step for spinal disc interventions.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[Complications after ileal conduit: Urinary diversion-associated complications after radical cystectomy].

Der Urologe. Ausg. A·2015
Same author

[Clinical and histopathological parameters of prostate cancer: influence of anthropometric indices].

Der Urologe. Ausg. A·2014
Same author

Fusion of Magnetic Resonance Imaging and Real-Time Elastography to Visualize Prostate Cancer: A Prospective Analysis using Whole Mount Sections after Radical Prostatectomy.

Ultraschall in der Medizin (Stuttgart, Germany : 1980)·2014
Same author

[Pulmonary hypertension: microRNAs in pathogenesis, diagnosis and therapy].

Pneumologie (Stuttgart, Germany)·2014
Same author

Endogenous α-calcitonin-gene-related peptide promotes exercise-induced, physiological heart hypertrophy in mice.

Acta physiologica (Oxford, England)·2014
Same author

[Outcome prediction in patients with Fournier's gangrene].

Der Urologe. Ausg. A·2013

Area of Science:

  • Spine surgery
  • Diagnostic imaging
  • Biomechanical testing

Background:

  • Diskograms are commonly used to assess disc degeneration.
  • Assessing intradiscal pressure and volume can provide biomechanical insights.
  • Current diagnostic routines may benefit from enhanced objective measures.

Purpose of the Study:

  • To investigate the correlation between intradiscal pressure/volume recordings and diskographic findings.
  • To evaluate the clinical utility of intradiscal pressure/volume testing in preoperative diagnostics.

Main Methods:

  • Collected 242 sets of intradiscal pressure/volume recordings and corresponding diskograms.
  • Performed statistical analysis to determine the correlation between variables.

Main Results:

  • A significant correlation (p < 0.01) was found between disk compliance and the degree of diskographic degeneration.
  • Intradiscal pressure/volume testing demonstrated high reliability and safety.

Conclusions:

  • Intradiscal pressure/volume testing is a reliable and risk-free method to assess disk degeneration.
  • This testing should be integrated into the preoperative diagnostic routine for patients undergoing spinal disc procedures like chemonucleolysis or percutaneous diskectomy.